4-3
Components
Test procedures
Results
Door switch
1. Refer to page 3-9 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1000)
Door open
Door closed
Continuity
Infinite
Outer Broil heater
1. Refer to page 3-10 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale : R x 1)
Normal: Approximately
23 Ω ± 10%
If not replace
NOTE: Ω Value was tested
at room temperature
(77˚F/25˚C)
Be careful. The element is
sensitive to temperature.
Convection heater
1. Refer to page 3-12 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale : R x 1)
Normal: Approximately
49 Ω ± 10%
If not replace
NOTE: Ω Value was tested
at room temperature
(77˚F/25˚C)
Be careful the element is
sensitive to temperature.
Oven lamp
1. Measure the resistance after cooling down
(Multiple meter scale: R x1)
Normal: Below 5 Ω.
If not replace