5-7
CONVERSION TO LP GAS
WARNING
• Turn off the electrical supply and
gas supply going to the range.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal
injury, death or electrical shock.
CAUTION
• Be careful when you work on the
gas range handling the sheet metal
part.
- Sharp edge may be present and you can cut
yourself.
5. CONVERT THE OVEN BURNER ORIFICES
1) OVEN LOWER BURNER(BAKE)
a) Remove oven door, oven bottom, frame
guide, nozzle case and oven burner
assembly.
b) Remove the orifice spud from nozzle holder
using a 13/32” or 10mm wrench.
c) Install the LP orifce spud(D) to the nozzle
holder. To prevent leakage, make sure the
orifice spud is securely screwed into the
nozzle holder.
2) OVEN UPPER BURNER(BROIL)
1) Remove oven door and Broil burner
assembly. Then remove the wire cover
using a phillips head screwdriver.
2) Release the connector of the lgniter.
3) Remove the orifice spud from nozzle holder
using a 13/32” or 10mm wrench.
4) Install the LP orifce spud(C) to the nozzle
holder. To prevent leakage, make sure the
orifice spud is securely screwed into the
nozzle holder.
6. Turn on the Electrical and Gas Supply to
continue with flame adjustment.
7. ADJUSTING THE AIR SHUTTER
For bake burner, adjust the Air Shutter for LP
gas, loosen the Philips head screw and rotate the
shutter to the fully open position as shown Fig.1.
NOTE: When converting the unit back to natural
gas the bake burners air shutter should be also in
fully open position.
For broil burner, adjust the Air Shutter for LP gas,
loosen the Philips head screw and rotate the air
shutter to the fully open position as shown Fig.1
(Refer to Fig.1)
NOTE: When converting the unit back to natural
gas the broil buners air shutter should be in
0.4inch (10mm) open position. (Refer to Fig.2)
Check the flame size. The flame should have
approximately 1-inch blue cones.
After 30 seconds of the burner operation, check
for flame stability.
If the flame is lifting off of
the burner ports gradually
reduce the air shutter
opening until flames have
stabilized. Some yellow
tipping may be normal
when used on LP.
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Screw
Air Shutter
Counterclockwise
to 0.4inch(10mm)
open position.
Screw
Air Shutter
Approx. 1”
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Counterclockwise
to remove
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Clockwise to install
Fig.1
Fig.2
Summary of Contents for LRG3091SB
Page 94: ......