4-3
Copyright ©
LG Electronics Inc. All rights reserved.
Only training and service purposes
Components
Test procedures
Results
Broil or bake igniter
1. Refer to page 3-9~3-10 for servicing
procedure.
2. Measure the resistance after cooling down.
(Multiple meter scale : R x 1)
Normal: 45 Ω ~ 400 Ω
(Room Temperature
Resistance)
If not replace
Oven (safety) valve
1. Refer to page 3-21 for servicing procedure.
2. Measure the resistance after cooling down.
(Multiple meter scale : R x 1)
Upside
Downside
Normal: Approximately
1 ~ 3 Ω
If not replace
Ignition switch
1. Refer to page 3-6~3-7 for servicing procedure.
2. Measure the resistance by rotating the cam of
each switch slowly.
(Multiple meter scale : R x 1)
40˚
80˚
approximately
40° ~ 80°
other
NO
COM
Continuity
NO
COM
Infinite
Summary of Contents for LRGL5821S