5-2
Copyright ©
LG Electronics Inc. All rights reserved.
Only training and service purposes
CONVERSION TO LP GAS
1) Remove grates, burner caps and burner heads.
2) Remove the brass orifice spud in the chimney
of each burner using a 13/32” or 10 mm nut
driver.
3) Install the LP orifice spuds into their correct
positions as described previously.
• LP (Propane) Gas Orifice Specifications
BURNER OUTPUT RATINGS: BTU/HR
LP(Propane) Gas. 10”W.C.P
MODEL
BURNER
BTU RATE
ORIFICE CODE
LRGL5825** / LRGL5823** / LRGL5821**
LF
12,000 / 10,000 / 10,000
104 / 95 / 95
LR
9,100
93
RR
5,000
69
RF
12,500 / 12,500 / 12,000
108 / 108 / 104
CTR
10,000
95
BROIL
12,500
H
BAKE
18,000
D
108
Top burner orifices
Broil and Bake burner orifices
Denotes orifice code
• Natural Gas Orifice Specifications
BURNER OUTPUT RATINGS: BTU/HR
Natural Gas, 5”W.C.P
MODEL
BURNER
BTU RATE
ORIFICE CODE
LRGL5825** / LRGL5823** / LRGL5821**
LF
17,000 / 12,000 / 12,000
190 / 155 / 155
LR
9,100
134
RR
5,000
102
RF
20,000 / 20,000 / 17,000
208 / 208 / 190
CTR
10,000
142
BROIL
13,500
P
BAKE
19,000
A
K
208
Top burner orifices
Broil and Bake burner orifices
Denotes orifice code
WARNING
• Turn off the electrical supply and
gas supply going to the range.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal
injury, death or electrical shock.
CAUTION
• Be careful when you work on the
gas range handling the sheet metal
part.
- Sharp edge may be present and you can cut
yourself.
4. CONVERTING THE SURFACE BURNERS
Remove the conversion kit (see illustration below).
LP orifice spuds have a orifice code on the top or
the side, denoting the location on the range where
it is to be installed.
Denotes
orifice
code
Top burner orifices
Broil and Bake
burner orifices
Conversion
kit
Summary of Contents for LRGL5821S
Page 71: ......