4-3
Door switch
Broil heater
Components
Test procedures
Results
1. Refer to page 3-9 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1000)
Door open
Door closed
Continuity
Infinite
1. Refer to page 3-10 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale : R x 1)
Normal: Approximately
23
Ω
± 10%
If not replace
NOTE:
Ω
Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
1. Refer to page 3-12 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale : R x 1)
Normal: Approximately
13.5
Ω
± 10%
If not replace
NOTE:
Ω
Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
Convection heater
Oven lamp
1. Measure the resistance after cooling down
(Multiple meter scale: R x1)
Normal: Below 5
Ω
.
If not replace
Summary of Contents for LSE4613BD