ENGLISH

ductwork design Tips

Wherever possible, reduce the number of transitions 

and turns to as few sharp angles as possible. Two 

staggered 45° angles are better than one 90°.
Keep turns as far away from the hood exhaust as 

possible, and allow as much space between bends 

as possible.
For best performance, use round ducts instead of 

rectangular, especially when elbows are required.
If multiple elbows are used, try to keep a minimum of 

24" of straight duct between them.
Avoid “S” or “back to back” use of adjacent elbows.
In regions where the weather gets extremely cold, 

use thermal breaks, such as a short section of non-

metallic duct, to avoid indoor heat loss. Locate the 

break as close as possible to the outside pass-

through point.
Do not use flexible metal duct.

do not

 use ductwork that is smaller in cross-sectional 

area than the recommended types above.

Power Supply

WArNiNg

 

The information in this manual should be 

followed exactly. Failure to do so could result 

in fire or electrical shock, causing property 

damage, personal injury or death.

 

All electrical work must by performed by 

qualified electrician or person with similar 

technical knowledge and background.

 

For personal safety, remove house fuse or open 

circuit breaker before beginning installation. Do 

not use extension cord or adapter plug with this 

appliance.

 

Follow national electrical codes or 

prevailing local codes and ordinances.

Electrical Supply

This appliance requires a 120V 60Hz electrical 

supply, and must be connected to an individual, 

properly grounded branch circuit, protected by a 15 or 

20 ampere circuit breaker or time delay fuse. Wiring 

must be 2 wire w/ ground. Please also refer to the 

Electrical Diagram label on product.

GREEN

WHITE
WHITE

BLACK

BLACK

GREEN

Wire cap,  

3 places

Junction box

To house circuit breaker 

panel or fuse box

uL/CSA approved 

NEMA strain relief

To range hood

3 Wire Connection to Junction Box

Cable Lock

A cable locking connector (not supplied) might 

also be required by local codes. Check with local 

requirements and codes, and purchase and install 

appropriate connector if necessary.

Cable Lock

Verify the Package Contents

unpack the parts box and verify that all parts and 

accessories have been included. If any item is 

missing or damaged, please contact the dealer 

immediately. Do not install a damaged or incomplete 

appliance.
Make sure you have everything necessary for proper 

installation before proceeding.

Summary of Contents for LSHD3080ST

Page 1: ...TALLATION GUIDE HOOD Read these instructions thoroughly before installing and operating the hood www lg com LSHD3689BD LSHD3089BD LSHD3680ST LSHD3080ST MFL70208702_00 Copyright 2017 LG Electronics Inc All Rights Reserved ...

Page 2: ...ifications 7 General Specifications 8 Dimensions 9 PRODUCT OVERVIEW 9 Parts 9 Accessories 10 Planning the Installation 10 Cabinet Layout 11 Ducting Options 12 Ducting Calculation Sheet 13 Power Supply 13 Verify the Package Contents 14 Installation Instructions 14 Mounting the Range Hood 15 Wiring Diagram ...

Page 3: ...customer Customer Keep these installation instructions for future reference and the local electrical inspector s use APPLIANCE DATA PLATE The appliance data plate contains the model and serial number information and the electrical requirements It is located inside the hood behind the filters on the back side of the chassis Remove the filters to view it All specifications subject to change without ...

Page 4: ... or any other appliance Also keep items that could explode such as aerosol cans away from cooktop burners ovens and range hoods Do not store flammable or explosive materials in adjacent cabinets or areas If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not use an additional speed control device with this un...

Page 5: ...he product is damaged when received immediately contact the dealer or builder This range hood must be installed and grounded by a qualified installer according to these installation instructions Install or locate this appliance only in accordance with these installation instructions and the requirements specified by the manufacturer of the cooktop or range Improper installation adjustment alterati...

Page 6: ... or element is in use Boil overs and greasy spills may smoke and or ignite Do not leave children alone or unattended in the area where the cooktop and range hood are in use Never allow children to sit or stand on an appliance Do not let children play with a range cooktop or range hood Do not store items of interest to children above or around the cooktop range or range hood The minimum vertical di...

Page 7: ...ds 5 Filters Aluminum mesh filters Total Connect Load 120 VAC 60 Hz 4 Amp Lights 120 VAC 8 W LED light strip Model Specific Model Number LSHD3689BD LSHD3680ST LSHD3089BD LSHD3080ST Filters 2 Weight Specifications Model Number Weight LSHD3689BD LSHD3680ST 37 lb 17 kg LSHD3089BD LSHD3080ST 35 lb 16 kg ...

Page 8: ...nd electrical wiring can be connected from either the top or the back of the hood 10 3 8 1 3 16 29 15 16 357 16 10 5 8 22 1 16 5 5 16 4 1 1 6 STANDARD min ducted 27 min recirc 31 max 48 18 7 16 Overall Dimensions A C B Model A B C LSHD3689BD LSHD3680ST 30 26 15 16 22 1 16 LSHD3089BD LSHD3080ST 36 26 15 16 22 1 16 ...

Page 9: ...Parts 1 4 5 2 3 Accessories Included Accessories Manual Duct cover bracket Duct cover Manual M6 x 1 3 M6 x 1 1 2 2 M4 x 8 2 Wire Caps 3 1 Hood 2 Icon Touch Control Panel 3 LED Strip Light 4 Mesh Filter 5 Side Panel Only for LSHD3689BD LSHD3680ST ...

Page 10: ...using elbows transitions and caps ALWAYS when possible reduce the number of transitions and turns If long duct run is required increase duct size from 6 to 7 or 8 If turns or transitions are required install as far away from hood duct output and as far apart as possible Minimum mount height between range top to hood bottom should be no less than 26 Maximum mount height should be no higher than 34 ...

Page 11: ...exhaust must be ducted to the outside Use metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Sample Ducting Options Roof Pitch w Flashing Cap blower housing ductless recirculating blower housing side wall cap w gravity damper Soffit or crawl space blower housing side wall cap w gravity damper blower housing ...

Page 12: ...x Ft 6 Round 45 elbow 9 Ft x Ft Subtotal column 1 Ft Duct pieces Equivalent length x number used Total 6 Round wall cap with damper 30 Ft x Ft 6 Round roof cap 30 Ft x Ft 6 round to 3 1 4 x 10 rect transition 1 Ft x Ft 6 round to 3 1 4 x 10 rect transition 90 elbow 16 Ft x Ft 7 10 Round 90 elbow 15 Ft x Ft 7 10 Round 45 elbow 9 Ft x Ft 7 10 Round wall cap with damper 30 Ft x Ft 7 10 Round roof cap...

Page 13: ...ed electrician or person with similar technical knowledge and background For personal safety remove house fuse or open circuit breaker before beginning installation Do not use extension cord or adapter plug with this appliance Follow national electrical codes or prevailing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and must be connected to an...

Page 14: ...need to be added behind the drywall if no studs are present Wall anchors may also be used but check local codes for compliance Failure to use suitable wall anchors and screws to hold the weight of the hood could result in personal injury or damage to cooking surface or counter 6 Remove the 2 aluminum mesh filters 7 Hang hood onto the mounting screws and hand tighten each screw Fig A1 Secure a thir...

Page 15: ...15 Wiring Diagram ENGLISH Wiring Diagram Models Volts HZ MAX Amps LSHD3089BD LSHD3080ST LSHD3689BD LSHD3680ST 120 60 4 ...

Page 16: ...16 Memo Memo ...

Page 17: ...AMPANA Lea atentamente estas instrucciones antes de instalar y poner la campana en funcionamiento www lg com LSHD3689BD LSHD3089BD LSHD3680ST LSHD3080ST MFL70208702_00 Copyright 2017 LG Electronics Inc Todos los Derechos Reservados ...

Page 18: ...mensiones 9 DESCRIPCIÓN GENERAL DEL PRODUCTO 9 Piezas 9 Lista de piezas 10 PLANIFICACIÓN DE LA INSTALACIÓN 10 Disposición de alacenas 11 Opciones de conducto 12 Hoja de cálculo de conducto 13 Suministro de energía 13 Verifique el contenido del embalaje 14 INSTRUCCIONES DE INSTALACIÓN 14 Montaje de la campana extractora 15 DIAGRAMA DE CABLEADO ...

Page 19: ...rucciones de instalación para referencia futura y para que las consulte el inspector Placa de datos del artefacto La placa de datos de este artefacto contiene información del número de serie y el modelo y los requisitos eléctricos Se encuentra ubicada dentro de la campana detrás de los filtros en la parte posterior del chasis Retire los filtros para verla Todas las especificaciones están sujetas a...

Page 20: ... de aerosol alejado de los quemadores de la cocina del horno y de la campana extractora No almacene materiales explosivos o inflamables en áreas o alacenas cercanas Si no sigue con exactitud la información de este manual podrían producirse un incendio o descarga eléctrica daños a la propiedad lesiones personales o la muerte No utilice un dispositivo adicional de control de velocidad con esta unida...

Page 21: ...mpana si se ha dañado caído se han dañado los cables eléctricos o si no está funcionando correctamente Si el producto está dañado cuando lo recibe póngase en contacto inmediatamente con el distribuidor o constructor Esta campana extractora debe ser instalada y conectada a tierra de acuerdo con las instrucciones de instalación por un instalador calificado Instale o coloque este aparato siguiendo so...

Page 22: ...é utilizando la superficie de cocción Nunca deje la cocina o la superficie de cocción sin vigilancia cuando un quemador u hornalla esté siendo utilizado Los derramamientos por ebullición o los derrames de grasa pueden emitir humo y o arder No deje niños solos o sin vigilancia en el área donde se estén utilizando la superficie de cocción y la campana extractora Nunca permita que los niños se siente...

Page 23: ... Filtros Filtros de malla de aluminio Carga total de conexión 120 V CA 60 Hz 4 A Luces 120 V CA tira de luces LED de 8 W Características específicas del modelo Número de modelo LSHD3689BD LSHD3680ST LSHD3089BD LSHD3080ST Filtros 2 Especificaciones de peso Número de modelo Peso LSHD3689BD LSHD3680ST 37 lb 17 kg LSHD3089BD LSHD3080ST 35 lb 16 kg ...

Page 24: ...el cableado eléctrico se pueden conectar desde la parte superior o posterior de la campana 10 3 8 1 3 16 29 15 16 357 16 10 5 8 22 1 16 5 5 16 4 1 1 6 Estándar mínimo por conducto 27 mínimo recirculando 31 máximo 48 18 7 16 Dimensiones generales A C B Modelo A B C LSHD3689BD LSHD3680ST 30 26 15 16 22 1 16 LSHD3089BD LSHD3080ST 36 26 15 16 22 1 16 ...

Page 25: ... 5 2 3 Lista de piezas Accesorios incluidos Manual Soporte de cubierta de conducto Cubierta de conducto Manual M6 x 1 3 M6 x 1 1 2 2 M4 x 8 2 Remates para cables 3 1 Campana 2 Panel de control táctil con iconos 3 Luz led 4 Filtros de malla 5 Panel lateral solo para LSHD3689BD LSHD3680ST ...

Page 26: ...nducto total disponible cuando se utilicen codos transiciones y casquetes SIEMPRE cuando sea posible reduzca el número de transiciones y giros Si se requiere un conducto largo aumente el tamaño del conducto de 6 a 7 o 8 Si se requieren giros o transiciones instálelas tan lejos como sea posible de la salida del conducto a la campana y tan separados como sea posible La altura de montaje mínima entre...

Page 27: ... conductos de metal Fije todas las conexiones con tornillos para metal y cubra todas las juntas con cinta plateada o cinta de conducto certificada Ejemplos de opciones de conducto Inclinación del techo con tapajuntas y tapa carcasa del ventilador recirculación sin conducto carcasa del ventilador tapa de la pared lateral con amortiguador de gravedad Sofito o entrepiso carcasa del ventilador tapa de...

Page 28: ... x Ft Subtotal columna 1 Ft Piezas de conducto Longitud equivalente x número usado Total 6 tope de pared redondo con compuerta 30 Ft x Ft 6 redondo tope de tejado 30 Ft x Ft 6 redondo para transición rectangular 3 1 4 x 10 1 Ft x Ft 6 redondo para transición rectangular 3 1 4 x 10 codo de 90º 16 Ft x Ft 7 10 redondo codo de 90º 15 Ft x Ft 7 10 redondo codo de 45º 9 Ft x Ft 7 10 Tope de pared redon...

Page 29: ...er realizado por un electricista cualificado o una persona con conocimiento y experiencia técnica similar Para su seguridad persona extraiga el fusible o abra el interruptor de circuitos antes de comenzar la instalación No utilice un extensor de cables o enchufe adaptador con este aparato Siga los códigos eléctricos nacionales o los códigos y ordenanzas locales Suministro eléctrico Este aparato re...

Page 30: ...entramado presente También pueden utilizarse anclajes de pared pero consulte los códigos locales para asegurar la conformidad El no utilizar anclajes y tornillos adecuados para la pared para soportar el peso de la campana podría resultar en daños personales o daños a la superficie de cocción o la encimera 6 Extraiga los 2 filtros de malla de aluminio 7 Coloque la campana sobre los tornillos de mon...

Page 31: ...15 DIAGRAMA DE CABLEADO ESPAÑOL DIAGRAMA DE CABLEADO Modelos Voltios Hz Amps Máx LSHD3089BD LSHD3080ST LSHD3689BD LSHD3680ST 120 60 4 ...

Page 32: ...LG Customer Information Center Register your product Online www lg com 1 800 243 0000 USA ...

Reviews: