6
10-6
CHECKING FLOW CHART BY FAILURE
Yes
No
Power On
4
Is the value of thermistor
normal?
Check: using the test mode
To enter the test mode, follow these steps:
1. press the “CLEAR” key
2. press the “BAKE”, ”BROIL” key at the same
time
3. press the “BAKE”, ”BROIL” key at the same
time again.
4. press the NUM “3” key
Normal :
the sensor value is from 70˚F to 90˚F at 25˚C.
Yes
Go to No 6
Yes
Power Off
5
Is the resistance of
thermistor normal?
Check:
Pins 1and 2 of CN5 wiring in main PCB
Normal
- approximately 1.09k
Ω
at 25˚C
No
CN5
Replace the
failed thermistor
Range Of the resistance
Heater
Min[
Ω
]
Max [
Ω
]
Broil Glowbar
45.0
400.0
Bake Glowbar
45.0
400.0
Gas Valve(Broil)
1
1.5
Gas Valve(Bake)
1
1.5
Replace the Relay PCB
(EBR52349701)
If it doesn’t work even though changing the Relay PCB,
you should replace the Main PCB.
(EBR52349501)