10-13
CHECKING FLOW CHART BY FAILURE
Yes
Power On
3
Is the value of thermistor
normal?
Check: using the test mode
To enter the testmode,
follow these steps:
1. press the “clear” key
2. press the “BAKE”, “BROIL” key at the same
time
3. press the “BAKE”, “BROIL” key at the same
time again.
4. press the NUM “3” key
Normal :
the sensor value is from 70˚F to 90˚F at 25˚C.
No
Replace
the Main PCB
(EBR52349501)
1
Power Off
Is the resistance of
thermistor normal?
Check:
Pins 1and 2 of CN5 wiring in main PCB
Normal
- approximately 1.09k
Ω
⁄ at 25˚C
CN5
Yes
No
No
Replace the
failed thermistor
2
Power Off
Is the Heater relay normal?
Measure the resistance of
heater relay and L.
Normal:
infinite
Abnormal:
continuity
Replace
the relay PCB
(EBR52349701)