INSTALLATION INSTRUCTIONS
FLEXIBLE CONNECTOR HOOKUP
Pressure regulator
Installer: Inform the
consumer of the
location of the gas
shut-off valve.
Adapter
Adapter
Gas shut-off valve
1/2” or 3/4”
Gas pipe
Flex connector
(6 ft. max.)
Gas Flow into Range
2. CONNECT THE RANGE TO GAS
Shut off the range gas supply valve before
removing the old range and leave it off until the
new hook-up has been completed.
Because hard piping restricts movement of the range,
the use of a CSA International-certified flexible metal
appliance connector should be used unless local
codes require a hard-piped connection.
NEVER reuse an old connector when installing a new
range.
To protect against gas leaks, use a qualified pipe joint
sealant on all external threads.
Install male 1/2” or 3/4” flare union adapter to the
NPT internal thread of the manual shut-off valve,
taking care to back-up the shut-off valve to keep it
from turning.
Install male 1/2” flare union adapter to the 1/2”
NPT internal thread at inlet of presure regulator.
Use a backup wrench on the presure regulator
fitting to prevent damage.
Connect flexible metal appliance connector to the
adapter on the range. Position range to permit
connection at the shut-off valve.
When all connections have been made, be sure
all range controls are in the off position and turn
on the main gas supply valve. Check for gas leaks
by using a liquid leak detector at all joints and
connections.
A
C
B
D
DO NOT USE A FLAME TO CHECK FOR GAS
LEAKS.
WARNING!
WARNING!
Isolate the range from the gas supply system by
closing its individual shut-off valve during any
pressure testing of the gas supply system at test
pressures equal to or less than 1/2” psig(3.5kPa).