4-14
Triple surface unit:
Right Front(RF)
Element
1. Refer to page 3-7 for the servicing procedure
2. Set the Multiple meter scale to the R x 1
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the (E1 & 1A)
and (E2 & 1A) and (E3 & 1A)
The meter should indicate.
- (E3 & 1A)
70.5
Ω
± 10%
- (E2 & 1A)
50.0
Ω
± 10%
- (E1 & 1A)
49.5
Ω
± 10%
5. Touch the ohmmeter test leads to limiter
terminals 1A and 2A. The meter should indicate
continuity(0
Ω
)
6. Touch the ohmmeter test leads to limiter
terminals 1B and 2B.
With the temperature below 150 ˚F, the meter
should indicate an open circuit(infinite).
With the temperature above 150 ˚F, the meter
should indicate continuity (0
Ω
).
Components
Test procedures
Results
Normal: Approximately 67
Ω
Normal: Approximately 48.5
Ω
Normal: Approximately 50
Ω
Normal: continuity
(below 0.5
Ω
)
If not replace
Below 150˚F
open circuit(infinite).
Above 150˚F
continuity (0
Ω
)
Summary of Contents for LSSE3026ST
Page 55: ...5 3 OVEN LIGHT Warming Drawer CR Cook top Element RR Cook top Element For Model LSE3092ST ...
Page 56: ...5 4 LR Cook top Element RF Cook top Element LF Cook top Element For Model LSE3092ST ...
Page 57: ...5 5 Broil Speed broil Boke Speed roost Warm Proof Easy clean ...
Page 58: ...6 1 COMPOSITION OF CONTROL 6 1 Wiring Diagram ...
Page 92: ... EV COOKTOP PARTS 3056 3215 3079 3006 3016 330M 330H 3205 3022 3204 330S 330S 3014 ...
Page 95: ......