CHECKING FLOW CHART BY FAILURE
3
Yes
Yes
Go to No 6
4
No
Range Of resistance
Plug in the unit
Is the resistance of
thermistor normal?
Check:
Pins 4 and 5 of CN31 in main PCB
Normal
- approximately 1.09k
Ω
at 25˚C
No
Replace the
defective
Thermistor
5
Yes
Unplug the unit
CN31
6
Replace the Relay PCB.
If the same phenomenon occurs even though
after replace Relay PCB, you should replace
the Main PCB
Heater
Resistance[
Ω
]
Approximately
Inner Broil
50
Outer Broil
23
Conv. Heater
23
Is the value of thermistor
normal? (Refer below)
Check with the test mode
To enter the test mode, follow these steps:
1. Press the any button, and encoder is
placed in the Off
2. Press the button in the following order
: +
→
→
_
→
→
Oven light
(Oven Light hold for 3 seconds).
3. Press the OVEN LIGHT button again.
(hold for 3seconds)
4. Select the “t3” by press the + button
5. Press the START button
Normal :
Thermistor value at room temp is from
70˚F to 90
˚