3-7
COMPONENT ACCESS
ASSMBL
ASSMBL
Y THE COOLING F
Y THE COOLING F
AN
AN
1. Turn off the electrical supply going to the range.
2. Pull the range away from the wall so that you
can access the rear panel.
3. Remove the back cover, remove 15 screws from
the back cover.
4. Remove vent trim rear cover, rear cover, vent
trim and vent cover.
5 Using a phillips head screwdriver remove the 2
side and 4 front and the 2 under screws of the
manifold.
6 Remove (11EA) hex-Phillips head screws on the
cook top. And lift it.
7. You can find cooling fan. Please be assembled
with a screws 2(EA) the cooling fan.
SPARK MODULE
screw
WARNING
• DISCONNECT power supply cord
from the outlet before servicing.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal
injury, death or electrical shock.
CAUTION
• Be careful when you work on the
gas range handling the sheet metal
part.
- Sharp edge may be present and you can cut
yourself.