4-2
COMPONENT TEST
Door locking Motor
Micro Switch
(normally open type)
Oven Sensor
1. Refer to page 3-13 for the servicing procedure
2. Measure the resistance
(Multiple meter scale: R x 1000)
1. Refer to page 3-13 for the servicing procedure
2. Measure the resistance
(Multiple meter scale: R x 1000)
1. Refer to page 3-14 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1000)
Normal: Approximately
1.09 k
Ω
± 10%
If not replace
Components
Test procedures
Results
NO
COM
Normal: Approximately
2.6 k
Ω
± 10%
If not replace
Abnormal: Infinite(open)
below 5
Ω
(shorted)
Door latch
open
Door latch
Locked
Continuity
Infinite
NOTE: After checking for the continuity of switch, make sure that they are
connected correctly
NOTE: Oven sensor is so sensitive to temperature
Do test after cooling down sufficiently
NOTE:
Ω
Value was tested
at room temperature
(77F/25˚C)