4-4
COMPONENT TEST
Oven (safety) valve
Ignition switch
Components
Test procedures
Results
1. Refer to page 3-21 for servicing procedure.
2. Measure the resistance after cooling down.
(Multiple meter scale : R x 1)
Normal: Approximately
1 ~ 3
Ω
If not replace
1. Refer to page 3-6~3-7 for servicing procedure.
2. Measure the resistance by rotating the cam of
each switch slowly.
(Multiple meter scale : R x 1)
approximately
40° ~ 80°
other
Continuity
Upside
Downside
40˚
80˚
Infinite