• LP (Propane) Gas Orifice Specifications
• Natural Gas Orifice Specifications
BURNER OUTPUT RATINGS; BTU/HR
BTU RATE
ORIFICE CODE
LF
LR
RR
RF
CTR
BROIL
BAKE
12,000
9,100
5,000
18,500
10,000
15,000
19,000
C
V
AA
U
T
A
H
Natural Gas, 5”W.C.P
BURNER
MODEL
5-1
CONVERSION TO LP GAS
CONVERTING THE SEALED BURNER
MODELGAS RANGE FOR USE ON LP
(PROPANE) GAS.
This range leaves the factory set for use with
natural gas. When converting to LP gas, keep these
instructions in case you need to convert back to
natural gas. And save the orifices removed from the
appliance for future use.
TOOLS REQUIRED:
• Adjustable wrench
• 13/32” or 10mm open-end wrench
5/16” or 8mm open-end wrench
16/32” or 16mm open-end wrench
• Phillips head screwdriver
• Flat bladed screwdriver(blade width approximately
3/32” across)
• Nut drivers : 13/32” or 10mm
5/16” or 8mm
WARNING
This conversion must be done by a
qualified technician or gas supplier in
accordance with the manufacturer’s
instructions and all codes and
requirements of the authority having
jurisdiction. Failure to follow
instructions could result in serious
injury or property damage.
The qualified agency doing this work
assumes responsibility for the
conversion.
BCONVERSION KITS
LP(PROPANE) GAS
CONVERSION INSTRUCTIONS
BURNER OUTPUT RATINGS; BTU/HR
BTU RATE
ORIFICE CODE
LF
LR
RR
RF
CTR
BROIL
BAKE
10,000
9,100
5,000
12,500
10,000
12,500
17,000
Q
M
W
G
Q
F
Y
UPSG3014ST / LSSG3016ST /
LSG4513ST / LSG5513ST
UPSG3014ST / LSSG3016ST /
LSG4513ST / LSG5513ST
LP(Propane) Gas. 10”W.C.P
M
Q
Q
G
W
BURNER
MODEL
Denotes orifice
code
Top burner and
Bake burner orifices (W=W)
Broil burner
orifices
F
W
Denotes orifice
code
Top burner and
Bake burner orifices
Broil burner
orifices
A
C