Troubleshooting
Icing Sensor Error (E IS )
1
Reconnect or
repair the
connector
Is the Connector disconnected
or loose between Main PCB and
sensor?
Yes
No
2
Check the Sensor resistance.
Is resistance 0 (Sensor short)?
Yes
No
Change the
Sensor
3
Check the Sensor resistance.
Is resistance OFF (Sensor open)?
Yes
No
Replace the
refrigerator
4
Check the Sensor resistance.
Is resistance normal?
Yes
5
Check the Temperature and
resistance refer to the table.
No problem?
Yes
6
Explain to customer
CON6
5
st
pin ~ 12
th
pin
Resistance [Ω]
-22ºF / -30ºC
40k
-13ºF / -25ºC
30k
-4ºF / -20ºC
23k
-13ºF / -25ºC
17k
14ºF / -10ºC
13k
23ºF / -5ºC
10k
32ºF / 0ºC
8k
CON6
Ice Maker Connector
CON6
47
Copyright © 2017 LG Electronics Inc. All rights
reserved. Only training and service purposes.
Summary of Contents for LSXC22396S
Page 98: ...Feb 2017 MFL62215930 ...