4-10
Components
Test procedures
Results
Variable Thermostat :
Lower oven switch
1. Refer to page 3-7 for the servicing procedure.
2. Set the Multiple meter scale to the R x 1000.
3. Disconnect all wires from Variable Thermostat
4. When turn on/turn off the knob, position measure the resistance
between L1 to H.
NOTE: Ω Value was tested at room temperature
(75F/24˚C)
L1
T2
T3
H
5. When turn on/turn off the knob, position measure the resistance
between T2 to T3.
L1
T2
T3
H
6. After check the single type, check the dual type at the same
procedure.
Knob Position
Results
Variable
Thermostat
OFF
L1-H
Infinite(open circuit)
T2-T3
Infinite(open circuit)
ON
L1-H
Continuity(short circuit)
T2-T3
Continuity(short circuit)