-3-9-
NOTE:
When servicing the burner housing or the valve, it is necessary to
service also the pipe which is designated.
1. Turn off the electrical supply and gas supply going to the range.
2. Remove the back cover, cooktop plate and manifold panel (see page
3-2, 3-4 and 3-7 for the procedure).
3. To remove the valve:
a) remove the back cover, cooktop plate and manifold panel (see page
3-2, 3-4 and 3-7 for the procedure).
b) Remove the fitting that you need to remove.
d) Remove the valve screw and remove the valve.
4. To remove the IGT
a) Remove the cooktop plate(See “REMOVING THE COOKTOP
PLATE” on page 3-7).
b) Remove 2 screws from IGT.
COMPONENT ACCESS
Screw Seal
Valve Screw
Valve Seal
Single Burner valve
Fitting
REMOVING THE COOKTOP PARTS
• DISCONNECT power supply cord from the outlet
before servicing.
• Replace all panels and parts before operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal injury, death or
electrical shock.
WARNING
• The 2 lock tabs on each igniter switch are fragile.
Tab breakage can occur if excessive release
pressure is applied.
• Check that the gas seal gasket on the screw and the
gas valve remain in place before installing the new
gas valve.
CAUTION