-4-3-
COMPONENTS
TEST PROCEDURE
RESULTS
Door switch
1. procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1)
Door open
Continuity
Door closed
Infinite
Oven lamp
1. Measure the resistance after cooling down
(Multiple meter scale: R x1)
Normal: Approximately 25.7 Ω ± 10% If not replace
Igniter Type-1
1. Remove wire leads
2. Measure resistance.
Normal: 45 Ω ~ 400 Ω(Room Temperature Resistance)
Replace if: Infinite(opened)
Igniter Type-2
1. Remove wire leads
2. Measure resistance.
Normal: 50 Ω ~ 800 Ω(Room Temperature Resistance)
Replace if: Infinite(opened)