5-10
COMPONENTS
TEST PROCEDURE
RESULTS
RELAY 2
FAN MOTOR
(Wire leads removed)
TURNTABLE
MOTOR
(Wire leads removed)
Check for continuity of relay 2 with an
ohm-meter.
(Remove wire leads from relay 2 and
operate the unit.)
NOTE : • A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
• MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
• WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
Normal: 350 ~ 450
Ω
Abnormal:
∞
or several
Ω
Normal: Approx.16 K
Abnormal:
∞
or several
Ω
POWER
LEVEL
20%
40%
60%
80%
100%
6 sec
10 sec
14 sec
18 sec
22 sec
16 sec
12 sec
8 sec
4 sec
0 sec
Measure the resistance.
(Ohm-meter scale: R x 100)
Measure the resistance.
(Ohm-meter scale: R x 1000)
Summary of Contents for MB-4334B
Page 9: ...SCHEMATIC DIAGRAM 4 3 ...
Page 28: ...6 2 13552A 14890A 13213A 13720D 14026A 14970A WTT028 13581A 13536A 13650A DOOR PARTS EV ...
Page 29: ...6 3 268711 24781S WTP013 23572A 23790D 23506A CONTROL PANEL PARTS EV ...
Page 30: ...6 4 WTT011 33052M 36549S 33390G 34370T 35889A 33112U WTP013 WTT010 OVEN CAVITY PARTS EV ...
Page 31: ...6 5 466001 466003 WSZ085 466001 43500A 43501A 44510A LATCH BOARD PARTS EV ...
Page 33: ...6 7 56170D 63303A WSZ002 WTT021 63302A 65006B BASE PLATE PARTS EV ...
Page 34: ... 36 ...