Installation Manual
11
ENGLISH
Fixing the
remote controller
Side of
remote Controller
L
N
N
L
RY1
RY2
INPUT
AC 220V
CN_Dry
Output AC 220V
5cm
Installation Method
4
Remove the installation paper before installing the
remote controller so that it can fit at the right place.
* Do not embed the remote controller into the wall. (It
may cause the breakdown of the temperature sensor.)
* If you want to install a number of remote controller at
the same place in a vertical line, install them at regular
intervals of 2cm. (It may cause the breakdown of the
temperature sensor.)
5
Install Dry contact Module
• Connect CN-CC with Remote controller by the cable(already linked previous step)
* Do not install the cable with a distance of 50 m or longer. (This can cause communication error.)
* When installing the cable, check whether the connector between the remote controller
and the product is installed properly.
The connector will not be connected when installed in opposite sides.
• Connect CN-Dry No.1 & No.4 with Actuator by the Power cable
Note
: Supply the power after connecting wired remote controller.
When you need to change wired remote controller, switch off the main power and change it.
If the wired remote controller is changed before switching off the main power, the option function of the indoor unit
can't be used. (option function like "slo" fan speed selection)
Note
: The power of actuator is supplied by output of power of Dry contact