Installer Setting – Option Function Setting
This function is used when air Cleaner, heater, humidifier, elevation grill, ventilation KIT are
installed additionally or the installed KIT is removed.
Select the code value and set value for each function using
F G
button.
Press and hold
B
button for more than 3 seconds to enter the installer settings mode.
- If pressing only once briefly, it will enter the user settings mode.
Make sure to press and hold for more than 3 seconds.
Press
B
button repeatedly to move to the applicable Function in the menu as below.
Press
K
button to save the setting.
Press
L
button to exit.
If no button is selected for about 25 seconds after setup, it exits the setup mode automatically.
If Set button is not selected before you exit, the changes will not apply.
Code value
Set value
❈
Set value for each function
00 : Not installed
01 : Installed
Function
Code
Plasma purification
20
Electric heater
21
Humidifier
22
Elevation grill
23
Ventilation kit
24
Auxiliary heater
25
In case of indoor unit that has one more additional stage in the Aux heater setting.
00: not installed
01: installed - general
02: installed - duct type
Installer Setting – Function Control Setting for Group Control
This function is to control the common functions or some functions based on the master indoor
unit criteria for group control.
Press and hold
B
button for more than 3 seconds to enter the installer settings mode.
- If pressing only once briefly, it will enter the user settings mode.
Make sure to press and hold for more than 3 seconds.
Move to the Function Settings for Group Control in the menu using
B
button and then it displays as
below.
Select the Function Settings for Group Control
using
F G
button.
Press
K
button to save the setting.
Press
L
button to exit.
If no button is selected for about 25 seconds after setup, it exits the setup mode automatically.
If Set button is not selected before you exit, the changes will not apply.
Code value for Function Setting
for Group Control settings
Set value
❈
Set value for Function Setting
for Group Control settings
00 : Common function
01 : Common function,
some indoor unit
master
criteria
• Common function, some indoor unit master criteria must be set for a group of the same
indoor unit series.
• In case of group control for the products which have different indoor models, use the exist-
ing group control mode by setting 00(common function use only).
ENGLISH