TROUBLESHOOTING
10
18
1. This TEST should be used for Factory test/Service test. Do not use this DIAGNOSTICTEST other than specified.
2. Activating the Heater manually with Door open may trp the Thermostat attached to the Heater, therefore do not
activate it manually, (Do not press the door switch to operate the heater while the door is open)
Activating the diagnostic test mode
1. Unit must be in Standby (unit plugged in, display off)
2. Press “
POWER
” while pressing “
More time
” and “
Less time
” simultaneously.
Data Display
-Tested under normal operation mode.
- Press the button as follows.
Pressing the
“START/PAUSE”button
None
Electric control
70~240
Measured
Moisture Value
70~240
Measured
Moisture Value
Current
temperature
Current
temperature
Water level in
sump
000
70~240
Measured
Moisture Value
Check all leds for operation.
Motor run counterclockwise.
Course LED's on.
All the LED's on with
buzzer.
Only option Button
LED's on.
LED's of Gentle and
Quick option glitter.
LED's of Time Delay,
Favorite, Anti-crease
and Buzzer options
glitter.
All the LED's of Sub-
Jog dial (Drying
Level) glitter.
All the LED's on.
All the LED's on / Off.
Displays Moisture Sensor Operation: If
moisture sensor is contacted with damp
cloth. The display number is below 180,
in normal condition.
Motor run clockwise.
Displays Moisture Sensor Operation: If
moisture sensor is contacted with damp
cloth. The display number is below 180,
in normal condition.
Motor run clockwise.
Heater run(Display the temperature of low
temperature themistor located under door.)
Motor run clockwise.
Pump run
Heater run(Display the temperature of high
temperature thermistor located in heater
assembly.)
Motor run clockwise.
Displays Moisture Sensor Operation: If
moisture sensor is contacted with damp
cloth. The display number is below 180,
in normal condition.
Auto Off
Motor
Motor
Motor
Motor off
Control Off
Motor+Heater 1
+Heater 2
Motor off + Heater off
Pump on
Motor + Heater 1
Once
Twice
3 times
4 times
5 times
6 times
7 times
8 times
No. of Button pressing
More time + Time Delay
More time + Favourite
Moisture data
Temperature sensed by low temperature thermistor (located under door)
Temperature sensed by High temperature thermistor (located in heater assembly)
Remaining water data by water level sensor
More time + Anti-Crease
More time + Drum Light
Display
CHECKING
ACTION
CHECKING
POINTS
DISPLAY