HOW TO USE
15
ENGLISH
Defrost Operation
If there is frost in the heat exchanger due to low indoor temperature, it automatically re-
moves the frost.
- During the operation, if ‘dF’ is displayed on the display, it automatically runs the defrost in the
heat exchanger inside the product.
- Compressor is stopped during the automatic defrost operation.
Ionizer
When you want to remove harmful bacteria in the air
- Select it by pressing Ionizer button.
- It removes harmful material in the air such as bacteria, virus, etc. using ionized air.
- You can use Ionizer function and dehumidification function at the same time.
- Ionizer can be used at any time regardless of dehumidifier function.
1,MFL69020710,영어 2017. 8. 21. 오후 7:00 페이지 15