13
Addr
ess
NO.
Description
Default
Maximum
Minimum
Unit
5315 FU2
#21
RST restart
0
1
0
5316 FU2
#22
Speed Search
0
15
0
BIT
5317 FU2
#23
SS Sup-Curr
100
200
80
5318 FU2
#24
SS P-gain
100
9999
0
5319 FU2
#25
SS I-gain
1000
9999
0
531A FU2
#26
Retry number
0
10
0
531B FU2
#27
Retry delay
10
600
0
0.1sec
531E FU2#30
Motor select
0
9
0
531F FU2#31
Pole number
4
12
2
5320 FU2
#32
Rated-Slip 200
1000 0 0.01Hz
5321 FU2
#33
Rated-Curr 36
2000
10 0.1A
5322 FU2
#34
Noload-Curr 7
2000 5 0.1A
5324 FU2
#36
Efficiency 72
100
70 %
5325 FU2
#37
Inertia rate
0
1
0
5327 FU2
#39
Carrier freq
50
150
10
0.1kHZ
5328 FU2
#40
Control mode
0
2
0
5329 FU2
#41
Auto tuning
0
1
0
532A FU2
#42
Rs (Note 4)
(Note 3)
5000
0
0.001ohm
532B FU2
#43
Rr (Note 5)
(Note 3)
5000
0
0.001ohm
532C FU2
#44
Lsigma (Note 6)
(Note 3)
MaxInduc
0
0.001mH
532D FU2
#45
SL P-gain
32767
32767
0
532E FU2
#46
SL I-gain
3276
32767
0
532F FU2
#47
proc PI mode
0
1
0
5330 FU2
#48
PID Ref
1
1
0
5331 FU2
#49
PID Ref Mode
0
5
0
5332 FU2
#50
PID Out Dir
1
1
0
5333 FU2
#51
PID F/B
0
2
0
5334 FU2
#52
PID P-gain
3000
9999
0
0.1%
5335 FU2
#53
PID I-time
300
320
0
0.1sec
5336 FU2
#54
PID D-time
0
9999
0
0.1msec
5337 FU2
#55
PID +limit
6000
maxFreq
0
0.01Hz
5338 FU2
#56
PID -limit
6000
maxFreq
0
0.01Hz
5339 FU2
#57
PID Out Inv
0
1
0
533A FU2
#58
PID OutScale
1000
9999
1
0.1%
533B FU2
#59
PID P2-gian
1000
9999
0
0.1%
533C FU2
#60
P-gain Scale
1000
1000
0
0.1%
5345 FU2
#69
Acc/Dec ch F
0
maxFreq
0
0.01Hz
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu