40
206-4310
If there is no user interaction within 10 seconds of the prompt for
confirmation, or if you select “NO” in the confirmation banner, the
STB will reboot and revert to the former resolution.
Note:
If this item is updated via a
Clone/Configuration (.tlx) file
loaded on a Pro:Centric server, no confirmation is required.
Note:
Refer to documentation for the applicable display panel(s)
to determine the appropriate resolution setting. The selected
resolution should be compatible with the display panel’s native
video output resolution. If necessary/desired, you can use STB
Zone
designations to create multiple profiles to differentiate item
105 settings by display panel brand. See Reference section, “Using
the STB’s Zoning Features,” for further information on STB Zones.
106 - ASP RATIO LOCK (Aspect Ratio Lock)
Set to 1 to retain previous aspect ratio with power off. Set to 0 to
retain default aspect ratio with power off. See item 096 DEF. ASP.
RATIO above.
107 - BANNER SELECT
Selects the type of banner to display during channel change. Set to
1 for channel label display, plus channel information (full banner).
Set to 0 for channel label display only (small banner).
108 - PANEL COM (Panel Communication)
Applicable only for LG Public Display TVs and Commercial
Monitors that use the RS-232C TELEVISION CONTROL port for
STB-to-display panel communication. Sets the display panel baud
rate:
0 = 1200
1 = 2400
2 = 9600 (default)
3 = 115200
109 - PANEL HNDSHAKE
Determines if communications includes handshaking. This setting
is only applicable for LG Public Display TVs and Commercial
Monitors that use the RS-232C TELEVISION CONTROL port for
STB-to-display panel communication. Set to 1 to enable hand-
shaking. Set to 0 to disable handshaking.
110 - PANEL DELAY
After the STB sends the turn ON command to the display panel,
the display panel requires time to complete its power on sequence
before it begins accepting commands from the STB. This item sets
the time, in seconds, to delay the STB’s initial communication with
the display panel. The default value is 8 seconds.
Note:
The amount of time required for the display’s power on
sequence varies by display panel brand/model. Thus, depending
on the brand/model of display panel connected to the STB, you
may be able to decrease or you may need to increase the Panel
Delay value, accordingly. For example, if you are using the STB
with an LG PW1000 or PW1500 projector, it is recommended that
you set the delay to 10 or more seconds.
Note:
This item does not apply to LG Hospitality display panels.
111 - PANEL VOL PRE (Panel Volume Preset)
Determines a preset fixed volume level (gain) to set in the display
panel. The audio signal (volume level) is dynamically controlled
in the STB. The default value is 100 to provide a typical 1:1 ratio
of volume level to sound output when the STB is connected to an
LG display panel.
Note:
Sound output may vary by display panel brand/model. Thus,
depending on the brand/model of display panel connected to the
STB, you may need to adjust the preset volume level to achieve
the desired sound output.
113 - PANEL TYPE
Sets the TLM command set to communicate with the display
panel. This setting is only applicable for LG Public Display TVs
and Commercial Monitors that use the RS-232C TELEVISION
CONTROL port for STB-to-display panel communication.
The default value (4) will be appropriate for most current display
models.
See Reference section, “Display Panel Specifications,”
to
determine the appropriate setting for the display panel being used.
116 - VIDEO MUTE EN (Video Mute Enable)
Applicable for analog channels only. If set to 1, video mutes
(blank screen) when no signal is present.
117 - FACT DEFAULT (Factory Default)
Set to 1 and press OK to restore the factory default settings of all
Installer Menu items. Once complete, the value returns to 0.
Caution:
If set to 1, this clears all STB Installer Menu
custom settings and restores the factory default
settings. It also clears the channel lineup, including
any assigned channel icons and custom text labels.
Note:
See also Reference section, “Restoring Factory Defaults on
the STB(s),” for further information.
119 - DATA CHANNEL
Set to 0 to disable. Set from 1 to 135 to match the RF channel
number that will be used by the Pro:Centric server as its data
channel. If left at the default value (255), the STB’s Data Channel
Auto Search feature will be enabled (see additional information
below)
. *
Installer Menu (Cont.)
*
PCS150R and later Pro:Centric servers do not support HRC or IRC cable channel frequencies.