Chapter 6 - Parameter Description [FU2]
117
FU2-93: Parameter Initialize
This is used to initialize parameters back to the factory
default values. Each parameter group can be initialized
separately.
Setting Range
LCD
7-Seg
Description
No
0
Displayed after initializing
parameters.
All Groups
1
All parameter groups are initialized
to factory default value.
DRV
2
Only Drive group is initialized.
FU1
3
Only Function 1 group is initialized.
FU2
4
Only Function 2 group is initialized.
I/O
5
Only Input/Output group is initialized.
EXT
6
Only External group is initialized.
COM
7
Only Communication group is
initialized.
APP
8
Only Application group is initialized.
☞
Note:
FU1-30 ~ FU1-37 [Motor Parameters] must be set
first after initializing parameters.
FU2-94: Parameter Lock
This function is used to lock the parameters from being
changed. When the parameters are locked, the display
arrow changes from solid to dashed line.
The lock and unlock code is ‘12’.
FU2-99: Return Code (7-Segment Keypad)
This code is used to exit a group when using a 7-
segment keypad. After pressing
PROG/ENT
key, set the
value to ‘1’ and press the
PROG/ENT
key again to exit.
FU2? Para. init
93 --- No ---
0
93
Factory Default:
No
0
FU2? Para. lock
94 0
0
94
Factory Default:
0
0
1
99
Factory Default:
1
Related Functions:
FU1-99 [Return Code]
I/O-99 [Return Code]
EXT-99 [Return Code]
COM-99 [Return Code]
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu