Chapter 5 - Parameter List
67
Keypad Display
Setting Range
Code
Description
LCD
7-Segment
LCD
7-Segment
Units
Factory
Default
Adj.
During
Run
Page
I/O-45
Fault Output Relay
Setting (30A, 30B, 30C)
Relay mode
45
000 to 111
(Bit Set)
-
010
Yes
133
I/O-46
26
Inverter Number
Inv No.
46
1 to 31
1
1
Yes
133
1200 bps
0
2400 bps
1
4800 bps
2
9600 bps
3
I/O-47
Baud Rate
Baud rate
47
19200 bps
4
-
9600 bps
Yes
133
None
0
FreeRun
1
I/O-48
Operating selection at
Loss of Freq. Reference
Lost command
48
Stop
2
-
None
Yes
I/O-49
Waiting Time after Loss
of Freq. Reference
Time out
49
0.1 to 120 [sec]
0.1
1.0 [sec]
Yes
133
None
0
Auto-A
1
I/O-50
Auto (Sequence)
Operation selection
Auto mode
50
Auto-B
2
-
None
No
I/O-51
Sequence Number
Selection
Seq select
51
1 to 5
1
1
Yes
I/O-52
The Number of Steps of
Sequence Number #
Step number
52
1 to 8
1
2
Yes
134
I/O-53
27
1
st
Step Frequency of
Sequence 1
Seq1 / 1F
53
0.01 to FU1-20
0.01 11.00 [Hz] Yes
I/O-54
Transient Time to 1
st
Step
of Sequence 1
Seq1 / 1T
54
0.1 to 6000 [sec]
0.1
1.1 [sec]
Yes
I/O-55
Steady Speed Time at 1
st
Step of Sequence 1
Seq1 / 1S
55
0.1 to 6000 [sec]
0.1
1.1 [sec]
Yes
Reverse
0
I/O-56
Motor Direction of 1
st
Step of Sequence 1
Seq1 / 1D
56
Forward
1
-
Forward
Yes
I/O-57
1
st
Step Frequency of
Sequence 2
Seq1 / 2F
57
0.01 to FU1-20
0.01 21.00 [Hz] Yes
135
I/O-58
Transient Time to 1
st
Step
of Sequence 2
Seq1 / 2T
58
0.1 to 6000 [sec]
0.1
1.1 [sec]
Yes
I/O-59
Steady Speed Time at 1
st
Step of Sequence 2
Seq1 / 2S
59
0.1 to 6000 [sec]
0.1
1.1 [sec]
Yes
Reverse
0
I/O-60
Motor Direction of 1
st
Step of Sequence 2
Seq1 / 2D
60
Forward
1
-
Forward
Yes
135
I/O-85
Step Frequency 8
Step freq-8
85
20.00 [Hz] Yes
I/O-86
Step Frequency 9
Step freq-9
86
10.00 [Hz] Yes
I/O-87
Step Frequency 10
Step freq-10
87
20.00 [Hz] Yes
I/O-88
Step Frequency 11
Step freq-11
88
30.00 [Hz] Yes
I/O-89
Step Frequency 12
Step freq-12
89
0 to FU1-20
0.01
40.00 [Hz] Yes
126
26
Code I/O-46 through I/O-49 are used in Option Board like RS485, Device, Net and F-net etc.
27
The ‘
Seq#
’ of code I/O-53 through I/O-60 varies according to the sequence number selected in I/O-51.
The parameter code may be extended to I/O-84 depending the number of steps set in I/O-52 because the steps can be set up to 8.
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu