background image

W: 

www.seconrenewables.com

 

 

 

T: 0191 516 6554

 

E: 

info@seconrenewables.com

 

 

 

The System can now be put into normal Operation 

 

Trouble Shooting 

 

Problem

 

Reason

 

Solution

 

 

 

 

   1 

 
 
 

 

Heating or 
Cooling is not 
satisfactory.

 

 

• 

Setting target temperature is 
not proper

.

 

• 

Set target temperature  correct ly

.

 

• 

Check if temperature is 

w

ater-based or air-based 

See "Remote 

sensor active

and 'Temp

sensor selection'  in Chapter6.

 

• 

Charged 

w

ater is not 

enough

.

 

• 

Check pressure gage and charge more 

w

ater until pressure gage 

is indication 2

~

2

.

5 Bar

 

 

• 

Water flo

rate is low

.

 

• 

Check if strainer gathers too much partices

If so, strainer 

should be cleaned

.

 

• 

Check  if  pressure  gage  indicates  above  4 Bar

 

• 

Check if 

w

ater pipe is getting closed due to stacked paticles or 

lime.

 

 
 
 
 
 
 

2

 

 
 

Although 
electric  po

w

er 

supply is OK 
(remote 
controller 
displays

 

information),  the 
unit does not 
start 

w

orking.

 

• 

Water inlet temperature is 
too high

.

 

• 

If 

w

ater inlet temperature is above 57 

°

C, the unit does not 

operated for the sake of system protection

 

 
 
 
 

 

• 

Water inlet temperature is 
too lo

w

.

 

• 

If 

w

ater inlet temperature is belo

°

C in cooling operation, the unit 

does not operated for the sake of system protection. Wait 

w

hile unit 

w

arms up the 

w

ater inlet temperature.

 

• 

If 

w

ater inlet temperature  is belo

15 

°

C in heating operation, the 

unit does not operated for the sake of system protection. Wait 

w

hile unit 

w

arms up to 18 

°

C the 

w

ater inlet temperature 

.

 

• 

If you are not using the back up heater  accessory (HA** 1M 
E1)

increase  the 

w

ater temperature 

w

ith the e

x

ternal heat 

source (heater

boiler).

 

If the problem persists, contact your dealer.

 

• 

If you 

w

ant to use the screed drying function, be sure to purchase 

and  install  back  up  hater  accessories  (HA 

** 

1M  E1)

.

 

 
 

 

3

 

 
 

Water pump 
noise

.

 

 

• 

Air purging is not 
completely  finished.

 

• 

Open the cap of air purge and charge more 

w

ater until 

pressure gage is indicating 2~2.5 Bar

 

• 

If 

w

ater does not splash out 

w

hen the tip(at the top of the hole) 

is pressed, then air purging is not completed yet. If 

w

ell purged, 

the 

w

ater 

w

ill splash out like fountain

.

 

• 

Water pressure  is lo

w.

 

• 

Check if pressure gage indicates above 0.3 Bar.

 

• 

Check if the e

x

panstion tank and pressure gage operates 

w

ell.

 

 

 

4

 

 

Water is flood 
out through 
drain hose

.

 

• 

Too much 

w

ater is 

charged

.

 

• 

Flood out 

w

ater by opening the s

w

itch of the safety valve until 

pressure gage is indicating 2~2.5 Bar.

 

• 

E

x

pantion tank is 

damaged

.

 

• 

Replace the e

x

pantion tank

 

 

 

5

 

 

 

DHW is not hot.

 

• 

Thermal protector  of 

w

ater 

tank heater is actived

.

 

• 

Open the side panel of the DHW tank and push the reset button 
of the thermal protector. (for more detail information, please 
refer to intallation  manual  of  DHW tank 

.

 

• 

DHW Heating is disabled.

 

• 

Select DHW Heating Operation and identify if icon is displayed on 
the remote conr toller

.

 

 

 

Summary of Contents for Therma V R32 Gen3

Page 1: ...LG Therma V R32 Gen3 Typical Installation with Third Party controls Installation and Setup Monobloc system Rev 1 0 January 14th 2022 ...

Page 2: ...set the room temperature at different times of the day The heat pump controls the domestic hot water temperature itself including for an optional sterilization cycle and is assisted by the immersion heater 2 port valves MUST not to be used upstream of the buffer The hot water control is managed through the LG controller Hot water takes priority over heating There is no electric heater inside the m...

Page 3: ...t we would recommend no less than 2m Allowance for the condensate to soakaway via a soakaway of to drain not to allow ice formation around the unit Anti freeze is recommended to protect again frost damage this should be premixed and added to the system we will go into further detail later The water quality should be tested against LG Requirements The Mains power must be turned on 6 Hours before st...

Page 4: ...y Power supplies sizes are All Electrical cable sizes should be checked on site by a NICEIC qualified electrician The Following Points must be followed o RCD Type C o Rotary Enclosed Isolation switch IP65 o Mandatory electricity meter fitted within an enclosed box o Ensure power cable does not touch refrigerant pipework ...

Page 5: ...t page Connections are made to the directly to the Monoblock via the 1st wiring centre as shown below Wiring back to terminals differs on older models until August 2020 Third Party controls should be wired through terminal 17 L and terminal 20 L2 using a NO Relay Please see below schematic for single Zone operation through 3rd party controls this should be integrated with the above for DHW control...

Page 6: ...firmed with the LG manual All Electrical work should be completed by NICEIC approved Electrician DIP Switch Settings The unit contains a number of DIP switches these must be set prior to powering up the unit in order to allow the unit to operate correctly and to allow some features to function The Dip Switches are laid out as the diagram below SW2 1 Off Master 2 Off 3 ON unit Outdoor Unit DHW tank...

Page 7: ...rature setting but an offset that can be applied to the default value of 0 as shown in the previous slide When the function is activated the default value is 5 Example if setting 10 is used entering water temp for judgment is reduced from 15 to 5 for protection starting entering water for condition release is reduced from 18 15 3 to 8 5 3 Pre Start Check Please check the following prior to startin...

Page 8: ...th OK 2 Use the Right hand button Select Setting Press and Hold the up Button for 3 Seconds 3 4 square boxes are shown enter the Password this is the software version in the right hand bottom corner of the screen You are now in the Installer Configuration menu The following setting need to be set for Basic operation Software Version ok ok Min Max 30 50 55 RADS 40 45 UFH ok ok ...

Page 9: ...W www seconrenewables com T 0191 516 6554 E info seconrenewables com ok Use Sun 1 00am ok ok ok 60 30 Force end time 1 ok Main Booster Heater ON ok ok 60 0 60 ok ok AS ABOVE ok ...

Page 10: ...8 C with a Design Flow temp of 50 C for Radiators Controler Video LG Therma V R32 Monobloc Installer Setting Guide Bing video Function Description Range Default Set Outdoor 1 Heat OUT 1 Heating Lower ambient Temp 25 35 c 10 c 2 8 c Outdoor 2 Heat OUT 2 Heating Higher ambient Temp 16 c 19 c Water1 Heat LW1 Heating higher Water Temp Dependant on Field Settings 35 c 50 c Water2 Heat LW2 Heating Lower...

Page 11: ...u Select Pump test run To use this function the antifreeze short pin must be open and switch No 2 in Option SW 3must be on Please See Earlier Section Regards Antifreeze Levels Through out this process the Flowrate should be observed to check it meet MI The system should be vent of air and check that it is full of water ...

Page 12: ...on the unit does not operated for the sake of system protection Wait while unit warms up to 18 C the water inlet temperature If you are not using the back up heater accessory HA 1M E1 increase the water temperature with theexternal heat source heater boiler If the problem persists contact your dealer If you want to use the screed drying function be sure to purchase and install back up hater access...

Page 13: ...ter fault Sensor fault Wire connection between remote controller and Main PCB assembly Heater should be tight Output voltage of PCB should be12 V DC 5 Bad communication between Main PCB assembly Heater and Main PCB assembly lnverter of the unit The connector for transmission is disconnected The connecting wires are misconnected The communication line is broken Main PCB assembly lnverter is abnorma...

Page 14: ... Connection Check Input Voltage Check PCB DC Link voltage sensor parts 24 Low High PressureSwitch Perception Error Low pressure is below 0 2 kgf cm2 High pressure is above 42 44kgf cm2 Pressure switch is self defective Check the low high pressure Check the connection of harness 26 DC CompressorPosition Compressor Starting fail error Check the connection of comp wire U V W Malfunction of compressor...

Page 15: ...rmistor connector Open Short 3 Defect of outdoor PCB lnverter 46 Problem in suctionpipe temperature sensor Open Short Soldered poorly Internal circuit error 1 Bad connection of thermistor connector 2 Defect of thermistor connector Open Short 3 Defect of outdoor PCB lnverter 52 PCB CommunicationError Checking the communication state between Main PCB and Inverter PCB Generation of noise source inter...

Page 16: ... EBR37798112 21 Check the soldered condition in the 22 23 pin of 1PM PFCM Check the screw torque of 1PM PFCM Check the spreadable condition of thermal grease on1PM PFCM Check the outdoor fan is driving rightly 65 Problem in HeatsinkTemperature sensor Abnormal value of sensor Open Short Check if there is defect of thermistor connector Open Short Check defect of outdoor PCB lnverter Display code Tit...

Page 17: ...ment for intervention Equally if any sediments are in the hydronic pipework they will be caught by the internal strainer Blockages in thestrainer can cause CH14 alarms In this case the strainers will need to be cleaned Recommendation once the unit has been installed advise the customers that it is quite likely and normal for a CH14 alarmto occur in the first two weeks This will give the customer r...

Page 18: ...6554 E info seconrenewables com Have you visited our web shop yet www seconrenewables com Secon Renewables Unit 87 Business Innovation Centre Wearfield Sunderland SR5 2TH T 0191 516 6554 E info seconrenewables com W www seconrenewables com ...

Reviews: