background image

WIT-300H Installation Manual 
Issue: 0.1C        

 

   Date:: 30/Jan/05

 

 

 
This Document Contains proprietary information and may not be reproduced or copied without express   
Written permission of a duly authorized representative of LG Electronics company
 

5

Safety Instructions 
 

WARNING!

 To reduce the possibility of electric shock, do not expose your phone to high humidity areas, 

such as the bathroom, swimming pool, etc. 
 

Always store your phone away from heat.

 Never store your phone in settings that may expose it to 

temperatures less than 32°F or greater than 104°F, such as outside during a snow storm or in your car on 

a hot day. Exposure to excessive cold or heat will result in malfunction, damage and/or catastrophic 

failure. 
 

Be careful when using your phone near other electronic devices.

 RF emissions from your mobile 

phone may affect inadequately shielded electronic equipment nearby. You should consult with 

manufacturers of any personal medical devices, such as pacemakers and hearing aides, to determine if 

they are susceptible to interference from your mobile phone. Turn off your phone in a medical facility or at 

a gas station. Never place your phone in a microwave oven as this will cause the battery to explode. 
 

IMPORTANT! 

Please read the TIA SAFETY INFORMATION before using your phone. 

Safety Information 

 

Please read and observe the following information for the safe and proper use of your phone and to 

prevent any unanticipated damage by accident. Also, keep the user’s manual in an accessible place at all 

times after reading it. 
 

 

Unplug the power cord and charger during a lightning storm to avoid electric shock or fire. 

 

Do not use your phone in high explosive areas, as the phone may influence high frequency devices. 

 

Do not put your phone in a place subject to excessive dust, and be careful to keep the minimum 

required distance between the power cord and heat sources. 

 

Unplug the power cord prior to cleaning your phone, and clean the power plug pin when it is dirty. 

 

Do not damage the power cord by bending, twisting, pulling, or heating. Do not use the plug if it is 

loose, as it may cause fire or electric shock. 

 

Hold the power cord plug firmly to plug and unplug the power cord. Ensure the plug is firmly 

connected. If it is not firmly connected, it may cause excessive heat or fire. 

 

Do not place any heavy item on the power cord. Do not allow the power cord to be crimped, as it may 

cause fire or electric shock. 

 

Be careful not to let the battery contacts touch metal conductors such as a necklace or coins. When 

shorted, it may cause an explosion. 

 

Do not disassemble or allow heavy impact to the battery as it may cause electric shock, short-circuit, 

and fire. Store the battery in a place out of reach of children. 

 

Using a damaged battery or placing a battery in your mouth, may cause serious injury. 

 

Do not place items with a magnetic strip, such as a credit card, phone card, bank book and a subway 

ticket, near your phone. The magnetism of the phone may damage the data stored in the magnetic 

strip. 

 

Do not hold or let the antenna come in contact with your body during a call. 

 

Talking on your phone for a long period of time may reduce the call quality due to heat generated 

during use. 

 

Do not allow excessive vibration or impact to the phone. 

 

When you do not use the phone for a long period time, store it in a safe area with the power cord 

unplugged. 

Summary of Contents for WIT-300H

Page 1: ...ion Manual THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION AND MAY NOT BE REPRODUCED OR COPIED WITHOUT EXPRESS WRITTEN PERMISSION OF A DULY AUTHORIZED REPRESENTATIVE OF LG ELECTRONICS COMPANY Jan 30 2005 LG Electronics Inc ...

Page 2: ...t be reproduced or copied without express Written permission of a duly authorized representative of LG Electronics company 2 REVISION HISTORY ISSUE DATE BY REMARK 0 1A Dec 02 04 SJ HWANG Preliminary Release 0 1B Dec 03 04 ALL Second Review Modification 0 1C Jan 30 05 SJ HWANG MFIM Registration USB TFTP Downloaing ...

Page 3: ... 1 GETTING STARTED 8 1 1 OPTIONS BASIC ENCLOSURE 10 1 2 WIRELESS NETWORK CELL 11 1 3 ACCESS POINT 12 1 3 1 WHICH ONE IS BETTER 12 1 3 2 HOW TO SET UP MULTIPLE APS 12 1 4 IPECS LIK 300 12 2 WIRELESS ENVIRONMENT SETUP 12 2 1 BASIC IEEE 802 11B NETWORK DIAGRAM 12 2 1 WHERE LIK 300 IS POSITIONED IN THE 802 11B NETWORK 13 2 2 AP CONFIGURATION 13 2 2 1 SSID 14 2 2 2 DTIM DATA TRAFFIC INDICATION MAP BEAC...

Page 4: ...4 PREFACE The main objective of this document is to provide an instruction for proper installation of WIT 300H Mechanical feature is simply described and operation condition is precisely addressed to prevent the WIT 300H from malfunctioning by environmental reason In advance of the environmental consideration please refer to this document it will help an installer in setting up basic circumstance ...

Page 5: ...lightning storm to avoid electric shock or fire Do not use your phone in high explosive areas as the phone may influence high frequency devices Do not put your phone in a place subject to excessive dust and be careful to keep the minimum required distance between the power cord and heat sources Unplug the power cord prior to cleaning your phone and clean the power plug pin when it is dirty Do not ...

Page 6: ...certified in accordance with the FCC regulations to verify that the product did not exceed the FCC SAR requirements The highest SAR level measured for this terminal was 0 128 mW g for body and 0 063 mW g for Head The design of this Terminal complies with the FCC guidelines these international standards and This terminal can be held in temporary confidentiality status CAUTION Use only the supplied ...

Page 7: ...tion Manual Issue 0 1C Date 30 Jan 05 This Document Contains proprietary information and may not be reproduced or copied without express Written permission of a duly authorized representative of LG Electronics company 7 ...

Page 8: ...nterference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits of a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment This equipment generates uses and radiate...

Page 9: ...glement sur le material broilleur du Canada This device complies with Class B Limits of Industry Canada Operations is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation The device is certified to the requirements of RSS 210 for 2 4GHz spread spectr...

Page 10: ...d the warranty Do not hold the antenna while the phone is in use Do not use the phone in designated no cellular phone use areas Do not expose the phone to high temperature or humidity Avoid getting your phone wet If the phone gets wet turn the power off immediately and remove the battery If the phone is non functional return it to the dealer for service Avoid shock or impact to the phone Options U...

Page 11: ...rgeable battery the delivery is strictly confirmed by LG Electronics Inc 1 2 Wireless Network Cell Fundamental topology of the IEEE 802 11b based wireless networking is the overlapped concatenation of more than two cell ranges The following figure shows the example of a cell area The WIT 300H is only 802 11b compliant its maximum frequency is 2 4GHz and 11 Mbps maximum bandwidth In terms of the tr...

Page 12: ... roaming CISCO and Orinoco APs are strongly recommended to customers 1 3 2 How to set up multiple APs Our recommendation is that one AP Access Point is used for one cell area If you would install more than two APs for a cell we recommend you to use the same SSID for each AP 1 4 iPECS LIK 300 The iPECS LIK 300 is a call controller of the WIT 300H Any activity of WIT 300H is notified to the iPECS LI...

Page 13: ... The iPECS LIK 300 and WIT 300H system work on top of this context 2 1 Where LIK 300 is positioned in the 802 11b network The following is a basic configuration of IEEE802 11b environment to enable WIT 300H and the iPECS LIK 300 1 WIT 300H AP IEEE 802 11b network SSID DTIM interval configuration within AP 2 AP iPECS LIK 300 Direct connection AP POE of iPECS LIK 300 Indirect connection AP HUB POE o...

Page 14: ... the SSID of WIT 300H you need to reboot it to apply the change 2 2 2 DTIM Data Traffic Indication Map Beacon DTIM is related to an interval of packet transmission By an inherent nature of the iPECS LIK 300 WIT 300H frequently uses multicast message for the communication with the iPECS LIK 300 The delivery of multicast message is affected by the DTIM parameter Beacon is an indication of packets bu...

Page 15: ...ission of a duly authorized representative of LG Electronics company 15 This section enumerates how you set up both SSID and DTIM in AP Orinoco 1 Open a page Interface Wireless You can see a edit box Network Name and DTIM Period 2 At Network Name enter SSID 3 At DTIM Period enter 1 Cisco 1 Open a page Network Interfaces Settings You can see a edit box DTIM 2 Enter 1 ...

Page 16: ...on and may not be reproduced or copied without express Written permission of a duly authorized representative of LG Electronics company 16 3 Open a page Security SSID Manager You can see a edit box SSID 4 Enter your SSID LinkSys 1 Open a page Setup Basic Info You can see a edit box SSID 2 Enter SSID ...

Page 17: ...d may not be reproduced or copied without express Written permission of a duly authorized representative of LG Electronics company 17 3 Open a page Advanced Advanced Wireless You can see a edit box DTIM 4 Enter 1 as DTIM value 3COM 1 Open a page Wireless Settings Configuration You can see a edit box SSID ...

Page 18: ... a edit box SSID 2 Enter SSID 3 DTIM configuration is not supported 2 2 4 Network Parameters Network parameters such as IP address netmask gateway are also to be configured since AP is bridging between the WIT 300H and the iPECS LIK 300 They are all to be set up with the same values to those in iPECS LIK 300 3 iPECS LIK 300 Setup 3 1 MFIM S W Version WIT 300H is recognized as special phone type in...

Page 19: ...y iPECS MFIM The registration can be completed by two modes like the LIP phone Remote mode and Local mode If you could use the MFIM located in your local LAN area you can register your phone in local mode otherwise you should use remote mode 3 2 1 Remote mode To register WIT 300H in remote mode you should know WIT 300H MAC address and IP A Basic settings 1 Enter the MAC address of WIT 300H in MFIM...

Page 20: ...at MENU Settings KTUset Direct Send 6 Enter MFIM IP at MENU Settings KTUset MFIM IP 7 Enter network mask of MFIM at MENU Settings KTUset MFIM Netmask B When you use static IP address 1 Enter IP address of WIT 300H at MENU Settings Network Static IP IP Address 2 Enter network mask of WIT 300H at MENU Settings Network Static IP subnet 3 Enter gateway IP of WIT 300H at MENU Settings Network Static IP...

Page 21: ...ose one of them at Auto menu shown here After setting these all up please turn off WIT 300H and then turn it on 4 S W Upgrade The S W image of WIT 300H composed of three binary files wit300hDbg bin Drv_C bin Drv_M bin 1 wit300hDbg bin It includes H W support kits WLAN driver Operating system core DSP LCD drivers etc 2 Drv_C bin It is the collection of business S W phonebook Messaging Screen manipu...

Page 22: ...ts new device through USB connection and requires Driver S W to be installed by popping up a window indicating the installation of new driver S W for the WIT 300H A Installing driver 1 Unzip S W zip file 2 Assigning usbio sys in the ZIP file to the window for new driver Now you are ready for downloading the S W B Downloading S W 1 Click and run FlashUp exe in the ZIP file 2 Browsing and selecting ...

Page 23: ... can download one of the S W images as follows A Entering Engineering mode 1 In idle screen press enter menu mode by pressing button 2 Enter 9 8 0 for Engineering Mode 3 Press buttons 2 1 3 3 9 2 OK as password 4 Now you are in the Engineering mode B Set up TFTP prameters 1 Select TFTP Setting 2 Enter the following values TFTP Server IP IP address of WIT 300H Subnet mask Gateway IP SSID File name ...

Page 24: ...0H phone is on rebooting with the new image Any error happens this screen is shown When any error occurs the WIT 300H will work abnormally Hence please try to download the image again until you succeed 5 Console Connection A Console connection 1 Plug in a console cable to WIT 300H and prepare for console monitoring by the PC through terminal emulator Setting parameter is 115200 baudrate no flow co...

Page 25: ...resentative of LG Electronics company 25 trying ping test at the WIT 300H For the ping test if the IP address of TFTP server is 10 10 10 221 enter ping 10 10 10 221 DO NOT FORGET DOUBLE QUOTATION AROUND THE IP ADDRESS PARAMETER The reply should be printed on the console successfully 2 showPhoneParam Listing up the configuration of WIT 300H 3 changePhoneParam Changing the configuration of WIT 300H ...

Reviews: