background image

Safety  Precautions

Owner’s Manual 

3

ENGLISH

Read all instruction bef

Read all instruction bef

ore using

ore using

To prevent injury to the user or other people and property damage, the following instructions must be followed.

Incorrect operation due to ignoring instructions will cause harm or damage; the seriousness is classified by the
following indications.

Meanings of symbols used in this manual are as shown below.

WARNING

This symbol indicates the possibility of death or serious injury.

CAUTION

This symbol indicates the possibility of injury or damage to property only.

Be sure not to do.

Be sure not to do.

Be sure to f

Be sure to f

ollo

ollo

w the instruction.

w the instruction.

W

W

ARNING

ARNING

Plug in the power plug
properly.

• Otherwise, it will cause electric

shock or fire.

Do not operate or stop the unit
by inserting or pulling out the
power plug.

• It will cause electric shock or fire.

Do not damage or use an
unspecified power cord.

• It will cause electric shock or fire.

Safety Precautions 

Installation

Operation

Do not place the power cord
near a heater.

• It may cause fire and electric

shock.

Do not use the power cord near
flammable or combustibles

 

materials such 

as gasoline, 

benzene,paint thinner, 

etc.

• It may cause explosion or fire.

Do not disassemble or modify
products.

• It may cause electric shock and

failure.

Gasolin

Buc

ket

full

Buc

ket

full

NO

Summary of Contents for ZD300

Page 1: ...MANUAL Please retain this owner s manual for future reference after reading it thoroughly DESHUMIDIFICADOR MANUAL DEL PROPIETARIO Le rogamos que guarde este manual del usuario para futura refer encia después de leerlo completamente MODEL MODELO ZD300 ...

Page 2: ...d many answers to common problems in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The dehumidifier is not intended for use by young children or invalids without supervis...

Page 3: ... Be sure not to do Be sure not to do Be sure to f Be sure to follo ollow the instruction w the instruction W WARNING ARNING Plug in the power plug properly Otherwise it will cause electric shock or fire Do not operate or stop the unit by inserting or pulling out the power plug It will cause electric shock or fire Do not damage or use an unspecified power cord It will cause electric shock or fire S...

Page 4: ...operating defumidifier when gas goes out It may cause explosion fire and burn Do not clean the dehumidifier with water Water may enter the unit and degrade the insulation It may cause an electric shock Turn off the power and breaker first when cleaning the unit Since the fan rotates at high speed during operation it may cause injury If water enters the product turn off the dehumidifier s power swi...

Page 5: ...on a table or shelf It may damage the dehumidifier or cause other damage or injury Make sure the dehumidifier is the correct size for the area you want to dehumidify It is not designed to dehumidify the entire house Install the dehumidifier properly on a floor table or shelf that is level and strong enough to support it when the water collection bucket is full It should withstand around 90 lbs 40k...

Page 6: ...2 F 6 C Low temperatures could cause coils to frost Do not put a pet or house plant where it will be exposed to direct air flow This could injure the pet or plant Do not use this appliance for special purposes such as pets foods precision machinery or art objects It is a general use appliance not precision equipment Do not use the water collected in the bucket for drinking purposes It is not sanit...

Page 7: ...xygen supply may be inadequate 3 Do not use this dehumidifier for non specified special purposes e g preserving precision devices food pets plants and art objects Such usage could damage the items 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the dehumidifier Exposure to water can destroy th...

Page 8: ...l notes NOTICE WARNING This appliance should be installed in accordance with national wiring regulations This guide acts as a guide to help to explain product features Features Symbols used in this Manual Power cord Cabinet Front Grille Air Filter Rear Grille Control panel Water bucket Handle Fan Spe ed Tim er Hig h Low 4 hr On Of f 2 hr On Of f Hu mid ity Co ntr ol Bu cke t ful l Au to Restart ...

Page 9: ...ified electrician replace the outlet before you use the dehumidifier WARNING Do not cut or remove the grounding prong from the power plug WARNING Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated and the wall receptacle is grounded through the house wiring WARNING If you have any doubt whether th...

Page 10: ...es To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage WARNING Never use the appliance with a broken adapter We strongly discourage the use of an extension cord due to potential safety hazards Temporary Use of an Extension Cord Temporary method Adapter...

Page 11: ...m 2hr On Off to 4hr On Off 6 BUCKET FULL Indicator This light glows when the bucket is full and needs to be emptied It also glows when the bucket is not properly positioned When bucket full indicator light glows the compressor and fan will turn OFF 7 AUTO RESTART Once the power is restored after a power outage the unit begins to operate at its previous operation setting The fan will run by default...

Page 12: ...o carry the bucket by supporting it from the bottom as well as by the handle Carrying by only the handle may cause the handle or bucket cover to break 2 Remove the drain hole cover Fig2 1 Connect a garden hose to the threaded drain hose connector Fig1 NOTICE NOTICE 4 Press the hose down and make sure the Arrow is pointing upward Fig4 1 4 2 The hose attachment will accept a standard garden hose fit...

Page 13: ...g of the coils due to colder air near the floor such as in a basement 3 Lift the bucket and place it in the dehumidifier making sure the slots on the bottom side of the bucket are positioned correctly 4 Rollers let you move the dehumidifier easily 1 Pull out the bucket cover 2 Brush off the residue in the bucket Clean the bucket by wiping with a cloth dampened in a mild detergent solution 3 Close ...

Page 14: ...nt Clean the grille with a vacuum attachment or brush Do not use bleach or abrasives Cleaning the air filter 1 Remove water bucket from the cabinet Pull out the air filter as shown above 2 Wash air filter with warm water and a mild detergent Rinse and dry it Replace it in place Electrical Shock Hazard Disconnect power supply cord from receptacle before performing any maintenance Be careful when cl...

Page 15: ... and windows to the outside This is normal Frost will usually disappear within 60 minutes This is normal Check the hose if one is attached See Removing and Emptying The Water Bucket Problem Possible Causes What To Do Dehumidifier does not start Dehumidifier does not dry the air as it should Dehumidifier runs too much Frost appears on the coils Fan noise Water on floor In case the Room humidity is ...

Page 16: ...consejos para la solución de problemas Si en primer lugar revisa nuestro cuadro de consejos para la solución de problemas es posible que no tenga necesidad de llamar al servicio técnico PRECAUCIÓN Póngase en contacto con un técnico del servicio autorizado para las reparaciones o el mantenimiento de esta unidad Póngase en contacto con un instalador para la instalación de esta unidad El deshumidific...

Page 17: ... No lo haga Siga las instrucciones AD ADVER VERTENCIA TENCIA Enchufe la clavija correctamente De lo contrario puede ocasionar un incendio o una descarga electrica No encienda ni apague la unidad insertando o retirando la clavija Causará una descarga eléctrica o incendio No dañe el cable ni utilice un cable de alimentación no especificado Podría producirse una descarga eléctrica o incendio No coloq...

Page 18: ...e entra agua en el producto apague el interruptor de contacto del deshumidificador Después de retirar la clavija del enchufe póngase en contacto con el centro de servicio técnico Causara fallo de la maquina o descarga electrica Si hay una fuga de gas ventile la habitación antes de utilizar el deshumidificador Podría producirse una explosión incendio y quemaduras No limpie el deshumidificador con a...

Page 19: ...ando esta instalada sobre una mesa o estanteria Podría dañarse el deshumidificador o producir otros daños o lesiones Asegúrese de que el deshumidificador tiene la capacidad adecuada para la zona que desea deshumidificar No está diseñado para enfriar la casa entera Instale el deshumidificador correctamente sobre el suelo una mesa o una estanteria lo suficientemente nivelada y fuerte como para sopor...

Page 20: ...Las bajas temperaturas podrían producir escarcha en los serpentines No coloque ningún animal o planta expuestos al flujo de aire directo Esto podria lesionar al animal o danar la planta No utilice este aparato para una finalidad especial como la deshumidificación de alimentos animales maquinaróa de precisión u objetos artisticos Es un aparato de uso general no un equipo de precision No utilice el ...

Page 21: ...shumidificador para finalidades no especificadas p ej preservar dispositivos de precisión alimentos animales plantas y objetos de arte Tal uso podría dañar estos elementos 1 No toque las partes metálicas de la unidad cuando retire el filtro Podrían producirse lesiones con los bordes metálicos afilados 2 No utilice agua para limpiar el interior del deshumidificador La exposición al agua puede destr...

Page 22: ...stalarse de acuerdo con la normativa nacional para instalaciones eléctricas Este manual sirve como guía para ayudar a explicar las características del producto Fan Spe ed Tim er Hig h Low 4 hr On Of f 2 hr On Of f Hu mid ity Co ntr ol Bu cke t ful l Au to Restart Panel de control Parrilla frontal Filtro de aire Asa Cubeta de agua Cable de Carcasa Parrilla posterior alimentación Instrucción Símbolo...

Page 23: ...dificador ADVERTENCIA no corte ni desmonte la patilla de toma de tierra de la clavija ADVERTENCIA si incorpora un terminal de tierra adaptador al tornillo de la cubierta del enchufe de la pared el aparato no se conecta a tierra a no ser que el tornillo de la cubierta sea de metal y no esté aislado y que el enchufe esté conectado a tierra a través de la instalación eléctrica doméstica ADVERTENCIA s...

Page 24: ...ión del adaptador hágalo con una mano en cada uno para evitar dañar el terminal de tierra Evite desenchufar frecuentemente el cable de alimentación ya que esto podría producir posibles daños en el terminal de tierra ADVERTENCIA no utilice nunca el aparato con un adaptador roto Desaconsejamos totalmente el uso de una alargadera debido a los potenciales riesgos de seguridad Método temporal Clavija a...

Page 25: ... cambia de 2hr On Off a 4hr On Off 6 Indicador BUCKET FULL este piloto se ilumina cuando la cubeta está llena y es necesario vaciarla También se ilumina cuando la cubeta no está colocada correctamente Cuando el piloto de cubeta llena se ilumina se apaga el compresor y el ventilador 7 AUTO RESTART una vez se reestablece la alimentación después de un corte de energía la unidad comienza a funcionar c...

Page 26: ...evarlo solo del asa puede provocar que esta o la cubeta se rompan AVISO AVISO Interruptor de control del nivel de agua 2 Retire la cubierta del orificio de drenaje Fig 2 1 Conecte una manguera de jardinería al conector roscado de la manguera de drenaje Fig 1 4 Presione la manguera hacia abajo y asegúrese de situar la Flecha en la parte superior Fig 4 1 4 2 La conexión de la manguera AVISO Al acopl...

Page 27: ...a del suelo como en un sótano 3 Levante la cubeta y colóquela en el deshumidificador asegurándose de que las ranuras de la parte inferior de la cubeta están colocadas correctamente 4 Las ruedas le permiten desplazar el deshumidificador fácilmente AVISO 1 Retire la cubierta de la cubeta 2 Limpie el residuo de la cubeta Limpie la cubeta frotando con un pano humedecido en una solucion de detergente s...

Page 28: ...e el panel frontal y la carcasa con un paño suave agua tibia y detergente suave Limpie la parrilla con un aspirador o cepillo No utilice blanqueadores ni abrasivos Limpieza del filtro de aire 1 Saque la cubeta de agua de la carcasa Retire el filtro de aire como se muestra arriba 2 Limpie el filtro de aire con agua tibia y un detergente suave Enjuáguelo y séquelo Vuelva a colocarlo en su sitio Ries...

Page 29: ... deshumidificar es demasiado grande Consulte con su distribuidor para comprobar si la capacidad es adecuada El aire está circulando por el deshumidificador Es normal Compruebe si la unidad está funcionando en modo ON Cambie el ajuste de humedad Cambie el ajuste de humedad Cierre todas las puertas y ventanas comunicadas con el exterior Es posible que la secadora de ropa esté expulsando aire cargado...

Page 30: ...30 Deshumidificador Nota ...

Page 31: ...iones en la Guía de funcionamiento accidente fuego inundaciones instalación inadecuada fuerza mayor modificaciones o alteraciones no autorizadas corriente eléctrica o tensión incorrecta o uso comercial o usos distintos a aquellos para los que fue diseñado 3 Por lo tanto los costes de reparación o sustitución de un producto defectuoso deberá correr por cuenta del consumidor Conserve su ticket y rec...

Page 32: ...ments or precautions in the Operating Guide accident vermin fire flood improper installation acts of God unauthorized modification or alteration incorrect electrical current or voltage or commercial use or use for other than intended purpose 3 Therefore the cost of repair or replacement of such a defective product shall be borne by the consumer Retain your Sales Receipt to prove date of purchase A...