Troubleshooting
8-18
InterReach Fusion SS Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620605-0-20 Rev A
8.3.2
Troubleshooting Using LEDs
The following troubleshooting guide is from the perspective that all Fusion Single-
Star equipment is installed, their cables are connected, and they are powered on; it is
assumed that the system was operating normally before the problem to be diagnosed
occurred. (Refer to Section 6.4.1.1, “Troubleshooting with Hub LEDs During Instal-
lation,” on page 6-13.)
Always use AdminBrowser, if possible, to troubleshoot the system. The Fusion Sin-
gleStar Hub LEDs are for backup troubleshooting. The RAU LEDs probably will not
provide additional information for troubleshooting.
8.3.2.1
Troubleshooting Fusion SingleStar Hub LEDs During Installation
Table 8-7
Troubleshooting Using Fusion SingleStar Hub LEDs During Installation
During
Installation
Fusion Hub
Port LEDs
State
Action
Impact
At Any Time
PORT
Red (60ppm)
flashing
Program band using Admin-
Browser, refer to Section 6.4.3,
“Configuring the System,” on
page 6-19.
The band is not programmed into the
Hub.
STATUS
Red
At Any Time
POWER
Red
Replace the Hub.
One or more power supplies are
out-of-spec.ification.