if the end face of the bearing block cling to the
end face of the balance shaft through the upper
and lower measuring holes, if the depth at the
two measuring holes are the same and if the
depth meets or is close to the theoretic depth
(The theoretic depth is 35±0.1 mm).
△
!
Note: Because of large axial
compression of the rubber bearing (more
than 20 mm) and the features of rubber,
when fastening the bolts with an air
wrench, the user needs to repeat the
fastening for many times. It is
recommended to fasten the bolts
alternately with a torque wrench after
the bolts are fastened to a certain
degree (when the fastening effect of air
wrench is not clear), until the torque of
the 7 bolts all reaches 540-600 N.m.
4) Service and Maintenance
a. Frequently check the following parts: check
upper/lower push rod and the connecting bolts
for damage and looseness. Check stop block for
dropping, leaf spring for break or dislocation
and leaf spring pressure block for crack.
b. Besides handling mandatory maintenance,
retighten the nut of bolt every 1,500-2,000 km
according to specified torque requirements.
Summary of Contents for MT86H
Page 9: ...MT86H Operation and Maintenance Manual 1 Chapter I Safety ...
Page 10: ...MT86H Operation and Maintenance Manual 2 ...
Page 18: ...MT86H Operation and Maintenance Manual 10 ...
Page 19: ...MT86H Operation and Maintenance Manual 11 Chapter II Product Introduction ...
Page 20: ...MT86H Operation and Maintenance Manual 12 ...
Page 25: ...MT86H Operation and Maintenance Manual 17 Chapter III Operation ...
Page 26: ...MT86H Operation and Maintenance Manual 18 ...
Page 64: ...MT86H Operation and Maintenance Manual 56 ...
Page 142: ...MT86H Operation and Maintenance Manual 134 ...
Page 143: ...MT86H Operation and Maintenance Manual 135 Chapter V Maintenance ...
Page 144: ...MT86H Operation and Maintenance Manual 136 ...
Page 160: ...MT86H Operation and Maintenance Manual 152 3 Lubrication diagram ...
Page 161: ...MT86H Operation and Maintenance Manual 153 Chapter VI Annex ...
Page 165: ...157 6 5 Schematic diagram of electrical system ...