LPL Reference
The Reference
24-18
Using the LI-6400
24
AICLOSE
Close an A/D structure
Initial:
A2dPtr
atd
Final:
-
See
AIGDEF
Define a group for analog measurements
Initial:
Num qSize, Num avgCnt, Num count, Num secs, Num grp, A2dPtr atd
Final:
Long code (0=ok, non-zero=failed)
See
AIGET
Get a set of A/D readings for a group
Initial:
Num numWanted, Num group
Final:
Long numRead
This causes the measured values to be loaded into the destination variables specified
in the
AIFREE
Free A/D space
Initial:
-
Final:
-
Deallocates internal memory structures used for A/D measurements. See
Table 24-7.
Parameters for
AIGDEF
qSize
The number of final readings that the operating system
should buffer. This value must be between 1 and N,
where (c*4+14)*N < 64000
and c is the number of channels in the group.
avgCnt
The number of raw readings that should be averaged to-
gether for each final reading.
count
The number of raw readings that should be taken during
the time interval
secs
.
secs
New readings are to be made available at this time inter-
val.
grp
The group number being defined (0ÉNg)
atd
The A/D structure returned by a prior call to
AIOPEN
.
Table 24-8.
Parameters for AIGET
numWanted
The number of sets of readings to transfer. This
should be less than or equal to the groupÕs qSize,
set via
AIGDEF
. The number of sets that are actually
available can be obtained from
AIREADY
group
The A/D structure returned by a prior call to
AIOPEN
.
numRead
The actual number sets of readings read.
Summary of Contents for LI-6400
Page 1: ...Using the LI 6400 Portable Photosynthesis System ...
Page 15: ...Part I The Basics ...
Page 16: ......
Page 174: ...Making Measurements Answers to Questions 4 56 Using the LI 6400 4 ...
Page 175: ...Part II Useful Details ...
Page 176: ......
Page 200: ...Standard Tools Power ON Hooks 5 24 Using the LI 6400 5 ...
Page 214: ...Real Time Data Real Time Graphics 6 14 Using the LI 6400 6 ...
Page 234: ...Environmental Control Light Control 7 20 Using the LI 6400 7 ...
Page 244: ...Light Sensor Considerations Gallium Arsenide Phosphide GaAsP Sensor 8 10 Using the LI 6400 8 ...
Page 288: ...Data Logging Making Your Own AutoPrograms 9 44 Using the LI 6400 9 ...
Page 289: ...Part III Working With Files ...
Page 290: ......
Page 312: ...The LPL File System Troubleshooting 10 22 Using the LI 6400 10 ...
Page 340: ...Downloading Files Using a Data Capture Program 11 28 Using the LI 6400 11 ...
Page 375: ...Part IV Configuration Issues ...
Page 376: ......
Page 420: ...Defining User Variables Old Style vs New Style 15 18 Using the LI 6400 15 ...
Page 454: ...Using an Energy Balance Further Reading 17 12 Using the LI 6400 17 ...
Page 455: ...Part V Maintenance Troubleshooting ...
Page 456: ......
Page 572: ...Troubleshooting Useful Information 20 46 Using the LI 6400 20 ...
Page 593: ...Part VI Programming ...
Page 594: ......
Page 622: ...Programming with LPL Compiler Directives 22 28 Using the LI 6400 22 ...
Page 846: ...Index I 16 Using the LI 6400 ...