background image

2

 

 Three soil temperature thermistors can be measured by a single chamber sensor interface, but the temperature data will have to be linked to the correct

chamber in post processing. There will also be a time delay between the flux and temperature measurement equal to the observation length times the
number of ports between where the sensor interface box is connected and where the flask containing the thermistor is connected.

Appendix: A list of parts available from LI-COR used to construct a
multiplexed flask system

One per flask

(includes all items below)

One per flask

1

1

1

1

3

Two to four

Two per flask

Two per flask

One per flask

One per flask

Two per flask

One if modifying an LI-8150-16

Description

 

LI-8150 Multiplexer

LI-8100A Analyzer Control Unit

AC to DC Power supply

Chamber sensor interface

Soil temperature thermistor 

Flask Sampling Kit

LI-COR Part number

LI-8150-16 or LI-8150-8

LI-8100A

8150-770-01

8150-661

8150-203

8150-670-16 or 8150-670-8

196-10534

210-01958-1

9981-173

9981-177

9881-204

140-04315

8150-250

300-07124

300-07125

300-07126

300-07127

167-07256

300-08118

300-07474

Two if modifying an LI-8150-8, or three if 

modifying an LI-8150-16.

Two if modifying an LI-8150-8 and venting 

the exhaust through one of the ports.

Three if modifying an LI-8150-8 and venting 

the exhaust through one of the ports.  Two

are included with the pump.

Two if using a port to supply ambient air

and vent exhaust.

One if not using a port to supply ambient air.

300-03367

300-03123

300-08151

Quick connect “Y”

Quick connect straight union

Quick connect plug

Filter

301-08119

One per flask or one for every three Soil 

temperature thermistors

2

Quantity

1

1

1

Rubber grommet

Silicone grease

Diaphragm pump

Flask pump power cable

Pump mounting plate

#6-32 x 3/8" Hex cap screw 

Bev-a-line tubing  (15m)

Male quick connect

Female quick connect

Quick-conn couple bulkhead

Quick-conn plug bulkhead

Seal washer

Quick connect elbow (1/8 NPT)

Quick connect elbow

These items included with either Flask Sampling Kit

11

Summary of Contents for LI-8100A

Page 1: ...early in half because the increased volume serves to dilute the change in CO2 mole fraction within the system As dC dt decreases the potential for error in the measurement due to instrument noise incr...

Page 2: ...s the mechanism by which CO2 and water vapor are exported from the system between measurements preventing condensation and excessively high CO2 mole fractions from developing in the flask The flushing...

Page 3: ...o brass plugs from the right hand upper and lower solenoid manifolds 2 Using an adjustable wrench replace the three brass plugs with quick connect elbows part 300 07474 and the one steel plug with a q...

Page 4: ...for flask measurements bottom right The flow path used during measurements is shown with blue arrows and the flow path used to flush flasks between measurements is shown with red arrows In both diagra...

Page 5: ...ver plate from the instrument by loosening the two thumb screws Figure 7A Mount the pump in the LI 8150 case by attaching the mounting plate to one of the two threaded holes normally used to attach th...

Page 6: ...thod 2 If dedicating a port to vent chamber exhaust and supply air to the auxiliary pump is undesirable the supply exhaust lines can be routed out of the LI 8150 by leaving the case open If using this...

Page 7: ...ments are made at near ambient tempera tures a measurement of chamber air temperature may not be required Figure 9 Mason jar lid fitted with plumbing connections and a soil temperature thermistor Two...

Page 8: ...as measured with a thermistor connected to V2 A volume correction can be made for the sample volume by entering a negative value for Extension Tube Volume cm3 Soil CO2 Flux System and LI 8150 Multiple...

Page 9: ...on air trapped in the measurement loop from the previous measurement with the air in the flask Figure 12 The change in CO2 mole fraction with time calculated for various deadband lengths using the dat...

Page 10: ...lated soil samples Jones and Kielland 2002 Haney et al 2008 and monitoring carbon fluxes from attached leaves and fruit Araki et al 1998 Kitano et al 1997 References Araki T M Kitano M Hamakoga and H...

Page 11: ...8100A 8150 770 01 8150 661 8150 203 8150 670 16 or 8150 670 8 196 10534 210 01958 1 9981 173 9981 177 9881 204 140 04315 8150 250 300 07124 300 07125 300 07126 300 07127 167 07256 300 08118 300 07474...

Page 12: ...licor com envsupport UK licor com LI COR Biosciences Global Headquarters 4647 Superior Street Lincoln Nebraska 68504 Phone 1 402 467 3576 Toll free 800 447 3576 Fax 1 402 467 2819 envsales licor com...

Reviews: