DL-AS61U-H2 Installation Guide
23
RS232 and TCP/IP Control
RS232 Settings: 9600 baud, 8 Data bits, 1 Stop bit, Parity = None
TCP/IP Settings: User defined IP address (default IP address:192.168.0.178), port 4001
There are no spaces between any of the characters in the command string. The commands are case sensitive.
Note:
In order to use the switching commands below, the switcher must be in manual switching mode only.
System will not respond to switching commands in auto switching mode.
Description
Command
Examples
Switch to HDMI input 1
HDMI1.
Command:
HDMI1.
Response:
HDMI OUT SWITCH TO 1!<CR><LF>
Switch to HDMI input 2
HDMI2.
Command:
HDMI2.
Response:
HDMI OUT SWITCH TO 2!<CR><LF>
Switch to HDMI input 3
HDMI3.
Command:
HDMI1.
Response:
HDMI OUT SWITCH TO 4!<CR><LF>
Switch to HDMI input 4
(USB-C input)
HDMI4.
Command:
HDMI4.
Response:
HDMI OUT SWITCH TO 4!<CR><LF>
Switch to HDMI input 5
(Display Port input)
HDMI5.
Command:
HDMI5.
Response:
HDMI OUT SWITCH TO 5!<CR><LF>
Switch to HDMI input 6
(VGA input)
HDMI6.
Command:
HDMI6.
Response:
HDMI OUT SWITCH TO 6!<CR><LF>
A/V Routing