background image

8 | EN

Copyright © Liberty Pumps, Inc. 2019 All rights reserved.

4617000L

Warranty

 

Liberty Pumps Wholesale Products Limited Warranty

Liberty Pumps, Inc. warrants that Liberty Pumps wholesale products are free from all factory defects in material and workmanship for a 

period of three (3) years from the date of purchase (excluding batteries). The date of purchase shall be determined by a dated sales 

receipt noting the model and serial number of the pump. The dated sales receipt must accompany the returned pump if the date of 

return is more than three years from the date of manufacture noted on the pump nameplate.
The manufacturer's sole obligation under this Warranty shall be limited to the repair or replacement of any parts found by the 

manufacturer to be defective, provided the part or assembly is returned freight prepaid to the manufacturer or its authorized service 

center, and provided that none of the following warranty-voiding characteristics are evident:
The manufacturer shall not be liable under this Warranty if the product has not been properly installed, operated, or maintained per 

manufacturer instructions; if it has been disassembled, modified, abused, or tampered with; if the electrical cord has been cut, damaged, 

or spliced; if the pump discharge has been reduced in size; if the pump has been used in water temperatures above the advertised rating; 

if the pump has been used in water containing sand, lime, cement, gravel, or other abrasives; if the product has been used to pump 

chemicals, grease, or hydrocarbons; if a non-submersible motor has been subjected to moisture; or if the label bearing the model and 

serial number has been removed.
Liberty Pumps, Inc. shall not be liable for any loss, damage, or expenses resulting from installation or use of its products, or for indirect, 

incidental, and consequential damages, including costs of removal, reinstallation or transportation.

There is no other express warranty. All implied warranties, including those of merchantability and fitness for a particular purpose, are 

limited to three years from the date of purchase. This Warranty contains the exclusive remedy of the purchaser, and, where 

permitted, liability for consequential or incidental damages under any and all warranties are excluded.

  

Pump does not deliver 

proper capacity.

Discharge partially closed or clogged.

Check the discharge line for foreign material, including 

ice if the discharge line passes through or into cold areas.

Check valve partially clogged.

Raise liquid level up and down to clear; remove check 

valve to remove obstruction.

Total head (lift height) is beyond pump's 

capability.

Route discharge piping to a lower level. If not possible, a 

larger pump may be required. Consult Liberty Pumps.

Obstruction in pump or piping.

Remove obstruction.

Pump operates noisily.

Piping attachments to building are too rigid.

Replace a portion of the discharge line with rubber hose 

or connector.

Worn bearings or other motor problem.

Return unit to authorized repair center for service.

Foreign objects in the impeller cavity.

Clean the impeller cavity.

Broken impeller.

Consult Liberty Pumps for information regarding impeller 

replacement.

Repeated tripping.

Circuit protection underrated.

Check rating and replace with proper size.

Other appliance on same circuit.

Pump requires separate circuit.

Pump is connected to an extension cord or 

wiring is inadequate or compromised.

Have an electrician check for proper wiring.

Improper voltage.

Have an electrician check all wiring for proper 

connections and adequate voltage and capacity.

Obstruction in pump.

Remove obstruction.

Foreign matter buildup.

Clean motor and float switch housing.

Table 1. Troubleshooting Matrix (continued)

Problem

Possible Cause

Corrective Action

Summary of Contents for LowPro41LP

Page 1: ...Pumps com Copyright Liberty Pumps Inc 2019 All rights reserved 4617000L This product supplied with a CSA Certified pump LowPro Series Low Profile Sewage System Models LowPro41LP 4 10 hp 115V LowPro51L...

Page 2: ...serious injury or death It is accompanied with an instruction intended to minimize potential risk of injury or death Warns of hazards which if not avoided will result in serious injury or death Warns...

Page 3: ...d for the voltage and amperage requirements of the pump as noted on the nameplate Overloaded branch circuit wires will get very hot and can catch on fire When used electrical outlets shall be simplex...

Page 4: ...tallation area is not complete If storage is necessary the LowPro system should remain in its shipping container It should be stored in a clean dry temperature stable environment where the pump system...

Page 5: ...a washing machine the preferred method is to drain the washer into a tub sink with a lint sock prior to the LowPro This requires periodically removing the access cover to clean lint and debris from th...

Page 6: ...nto the brass closet flange The foam gasket material on the spacer s must be facing down The spacer s will not be secured to the closet flange so use care not to move them during the installation of t...

Page 7: ...sin or other obstruction Position the pump or float switch so that it has adequate clearance for free movement Insufficient liquid level Verify the liquid level is allowed to rise enough to activate t...

Page 8: ...e of its products or for indirect incidental and consequential damages including costs of removal reinstallation or transportation There is no other express warranty All implied warranties including t...