6. Specifications 

MODEL 

6K 

10K 

CAPACITY* 

6000 VA / 4800 W 

10000 VA / 8000 W 

INPUT 

Voltage 
Range 

Low Line Loss 

110 VAC ± 3 % at 50% Load; 176 VAC ± 3 % at 100% Load 

Low Line Comeback 

Low Line Loss V 10V 

High Line Loss 

  300 VAC ± 3 % 

High Line Comeback 

High Line Loss Voltage - 10V   

Frequency Range 

46Hz ~ 54 Hz @ 50Hz system 
56Hz ~ 64 Hz @ 60Hz system 

Phase 

Single phase with ground 

Power Factor 

 0.99 at 100% Load 

OUTPUT 

Output voltage 

208/220/230/240VAC 

AC Voltage Regulation   

± 1% 

Frequency Range   
(Synchronized Range) 

46Hz ~ 54 Hz @ 50Hz system 
56Hz ~ 64 Hz @ 60Hz system 

Frequency Range (Batt. Mode) 

50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz 

Overload 

AC mode 

100%~110%: 10min

110%~130%: 1min

>130% : 1sec 

Battery mode 

100%~110%: 30sec

110%~130%: 10sec

>130% : 1sec 

Current Crest Ratio 

3:1 max 

Harmonic Distortion 

 3 % @ 100% Linear Load; 

 6 % @ 100% Non-linear Load 

Transfer 
Time 

Line

Battery 

0 ms 

Inverter

Bypass 

0 ms 

Inverter

ECO 

<10 ms 

EFFICIENCY 

AC mode 

> 89% 

Battery Mode 

> 88% 

BATTERY 

Standard 
Model 

Type & Numbers 

12 V / 7 Ah x 20 

12 V / 9 Ah x 20 

Recharge Time 

3 hours recover to 90% capacity 

4 hours recover to 90% capacity 

Charging Current   

2 A ± 10% (max.) 

2 A ± 10% (max.) 

Charging Voltage   

13.65 V ± 1%   

Long-run 
Model 

Type 

Depending on applications 

Numbers 

16 

– 20** 

Charging Current   

4 A ± 10% (max.) 

4 A ± 10% (max.) 

Charging Voltage 

13.65 V ± 1%   

PHYSICAL 

Standard 
Model 

Dimension,   
DXWXH(mm) 

UPS unit: 580X438X133 

Battery pack: 580X438 X133 

UPS unit: 668X438X133 

Battery pack: 580X438 X133 

Net Weight (kgs) 

UPS unit: 17   

Battery pack: 57 

UPS unit: 20 

Battery pack: 63 

Long-run 
Model 

Dimension, 
DXWXH(mm) 

580 X 438 X 133 

668 X 438 X 133 

Net Weight (kgs) 

17 

20 

ENVIRONMENT

 

Operation Temperature 

0 ~ 40°C (the battery life will down when > 25°C) 

Operation Humidity 

<95 % and non-condensing 

Operation Altitude** 

<1000m*** 

Acoustic Noise Level 

Less than 55dB @ 1 Meter 

Less than 58dB @ 1 Meter 

MANAGEMENT 

Smart RS-232 or USB 

Supports Windows®  2000/2003/XP/Vista/2008, Windows®  7, Linux, Unix, and MAC 

Optional SNMP 

Power management from SNMP manager and web browser 

* Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC. 
**

 When using internal batteries from 16-19, the unit will de-rate according to the below formula: P = P

Rating

 x (N/20 x 100%).

 

***If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m. 

Product specifications are subject to change without further notice.

 

Summary of Contents for Adapt BX 10K

Page 1: ...Single Phase Online UPS Liebert Adapt BX User Manual 6k 10kVA...

Page 2: ...4 UPS Installation for Parallel System 6 2 5 Software Installation 6 3 Operations 7 3 1 Button Operation 7 3 2 LED Indicators and LCD Panel 7 3 3 Audible Alarm 9 3 4 Single UPS Operation 10 3 5 Parall...

Page 3: ...for ventilation UPS has provided earthed terminal in the final installed system configuration equipotential earth bonding to the external UPS battery cabinets The UPS can be installed only by qualifie...

Page 4: ...000 4 3 Level 3 EFT IEC EN 61000 4 4 Level 4 SURGE IEC EN 61000 4 5 Level 4 CS IEC EN 61000 4 6 Level 3 Power frequency Magnetic field IEC EN 61000 4 8 Level 3 Low Frequency Signals IEC EN 61000 2 2 W...

Page 5: ...lug One parallel cable only available for parallel model One share current cable only available for parallel model NOTE Before installation please inspect the unit Be sure that nothing inside the pack...

Page 6: ...as its rated current is less than the UPS s maximum input current Otherwise the receptacle may be burned and destroyed 2 Switch off the mains switch in the building before installation 3 Turn off all...

Page 7: ...ry The battery type and voltage may be different If you connect them together it maybe causes the hazard of electric shock or fire Warning Only for long run model Make sure a DC breaker or other prote...

Page 8: ...g to the section 2 3 2 Connect the output wires of each UPS to an output breaker 3 Connect all output breakers to a major output breaker Then this major output breaker will directly connect to the loa...

Page 9: ...button to display next selection in setting menu Mute Down Button Mute the alarm Press and hold the button more than 0 5s to mute the buzzer Please refer to section 3 4 9 for details Down key Press t...

Page 10: ...y voltage information Indicates the output voltage frequency or battery voltage Vac output voltage Vdc battery voltage Hz frequency Load information Indicates the load level by 0 25 26 50 51 75 and 76...

Page 11: ...lt mode Beeping continuously Warning Overload Beeping twice every second No Low battery Beeping once every second Battery unconnected Over charge EPO enable Fan failure Over temperature Charger failur...

Page 12: ...rned on and enter to Battery mode 3 Connect devices to UPS After the UPS is turned on you can connect devices to the UPS 1 Turn on the UPS first and then switch on the devices one by one the LCD panel...

Page 13: ...7 LCD setting section 6 Test the batteries 1 If you need to check the battery status when the UPS is running in AC mode CVCF mode ECO mode you could press the Test button to let the UPS do battery se...

Page 14: ...t off you should remove the cover of maintenance bypass switch on the rear panel and turn the maintenance switch to BPS position first 3 Switch off the input breaker and switch off the battery breaker...

Page 15: ...the parallel models and follow the wiring refer to section 2 3 3 Install the new parallel system refers to the previous section 3 Remove one unit from the parallel system 1 If the bypass is abnormal...

Page 16: ...B Subtract ADD Add ON On OFF Off FBD Not allowed OPN Allow RES Reserved 3 7 LCD Setting There are three parameters to set up the UPS Refer to following diagram Parameter 1 It s for program alternative...

Page 17: ...tput voltage in parameter 3 208 Presents output voltage is 208Vac 220 Presents output voltage is 220Vac 230 Presents output voltage is 230Vac 240 Presents output voltage is 240Vac 02 Output frequency...

Page 18: ...e default value is 110V Parameter 3 Set the acceptable high voltage for bypass Setting range is from 231V to 276V and the default value is 264V 04 Frequency range for bypass Interface Setting Paramete...

Page 19: ...Hz 08 Bypass mode setting Interface Setting Parameter 2 OPN Bypass allowed When selected UPS will run at Bypass mode depending on bypass enabled disabled setting FBD Bypass not allowed When selected i...

Page 20: ...battery 13 Battery voltage adjustment Interface Setting Parameter 2 Select Add or Sub function to adjust battery voltage to real figure Parameter 3 the voltage range is from 0V to 5 7V the default va...

Page 21: ...output for energy saving LCD display CVCF mode Description When input frequency is within 46 to 64Hz the UPS can be set at a constant output frequency 50 Hz or 60 Hz The UPS will still charge battery...

Page 22: ...ages in LCD panel LCD display 3 9 Fault Code Fault event Fault code Icon Fault event Fault code Icon Bus start failure 01 None Negative power fault 1A None Bus over 02 None Battery SCR short circuited...

Page 23: ...ing twice every second Battery unconnected Beeping every second Over charge Beeping every second EPO enable Beeping every second Fan failure Over temperature Beeping every second Charger failure Beepi...

Page 24: ...oads from UPS output first Then shut down the UPS and restart it Fault code is shown as 43 The icon lights on LCD display and alarm beeps continuously UPS is overload too long and becomes fault Then U...

Page 25: ...required precautionary measures may replace batteries and supervise operations Unauthorized persons must be kept well away from the batteries Verify that no voltage between the battery terminals and...

Page 26: ...2 A 10 max Charging Voltage 13 65 V 1 Long run Model Type Depending on applications Numbers 16 20 Charging Current 4 A 10 max 4 A 10 max Charging Voltage 13 65 V 1 PHYSICAL Standard Model Dimension DX...

Page 27: ...25...

Reviews: