background image

11

LIMITED WARRANTY

Liebert Corporation extends the following LIMITED WARRANTY to the purchaser
and  to  its  customer  (collectively  referred  to  as  the  "Purchaser"):  the  enclosed
Uninterruptible  Power  System  (UPS)  and  components  are  free  from  defects  in
materials and workmanship under normal use, service, and maintenance FOR A
PERIOD OF TWO YEARS FROM THE DATE OF ORIGINAL PURCHASE from
Liebert or the Liebert dealer or retailer. THE FOREGOING WARRANTY IS THE
ONLY WARRANTY GIVEN  AND  NO  OTHER  WARANTY IS  PROVIDED,
EXPRESS 

OR 

IMPLIED, 

INCLUDING 

WITHOUT

LIMITATION,

MERCHANTABILITY OR  FITNESS  FOR  A PARTICULAR  PURPOSE.  Certain
aspects  of  disclaimers  are  not  applicable  to  consumer  products  acquired  by
individuals and used for personal, family, or household purposes (as distinguished
from industrial or other purposes). Local laws may not allow limitations on how long
an  implied  warranty  lasts,  so  the  above  limitation  may  not  apply  to  you.  This
warranty gives you specific legal rights, and you may have other rights which vary
according to local law.

Certain  repairs  or  services  are  the  responsibility  of  the  Purchaser  and  the
Purchaser is expected to pay for them. This warranty does not extend either to
products with removed or altered serial numbers or to any losses or damages due
to act of God or source external to the product, misuse, accident, abuse, neglect,
negligence,  unauthorized  modification,  alteration,  or  repair,  use  beyond  rated
capacity,  or  improper  installation,  maintenance,  application  or  use,  including,
without limitation, use in a manner contrary to the accompanying instructions or
applicable codes. WARNING: Warranty is void if the battery is allowed to discharge
below the minimum battery cutoff point.  To prevent such discharge DO NOT leave
the unit power switch "ON" for more than two (2) days without AC power being
supplied to the UPS. The battery must be recharged every four (4) to six (6) months
when not in use.

If the UPS fails to conform with the above warranty within the two year warranty
period,  Liebert  will  repair  or  replace  the  UPS,  at  Liebert's  option.    Repairs  or
replacements are warranted for the remainder of the original warranty period.  To
make a warranty claim, purchaser should call a Liebert Representative to obtain
a  Returned  Goods  Authorization  number  and  shipping  instructions.  Return
transportation costs to Liebert are the responsibility of the Purchaser.

"LIFE SUPPORT" APPLICATIONS

Due to the diversity of applications and considerations to be applied in each case,
Liebert does not recommend or knowingly sells its products for such use.

The responsibility for risk assessment and management in applications where the
malfunction or failure of the UPS could be reasonably expected to give rise to a
risk of human life shall be the sole responsibility of the purchaser. Liebert accepts
no liability for consequential harm in such applications.

Summary of Contents for PowerSure Personal XT 1250 VA

Page 1: ...450 700 1250 VA 230V PowerSureTM Personal XT USER MANUAL English Deutsch Fran ais Italiano Espa ol...

Page 2: ...OR OTHER APPLICATIONS Store in safe place if not required at this time 4 This UPS must be earthed at all times during operation Connect only to a mains supply socket outlet with an earth connection A...

Page 3: ...stable cart stand or table Do not place UPS under direct sunlight or close to heat emitting sources Do not place UPS power cord in any area where it may get damaged by heavy objects Follow all warning...

Page 4: ...ovides conditioned power to microcomputers and other sensitive electronic equipment PowerSure OUTPUT Lead acid battery inside the enclosure Blei Akkumulator innerhalb des Gehause INPUT FUSE 250V 5A T...

Page 5: ...0V 50 60Hz 4 0A 1 OUTPUT 230V 50 60Hz 700VA 420W 3 1A MADE IN CHINA Remove from Box Remove Plug from Units and replace in UPS Press ON Button Plug Units s into UPS 110 mm 0 40 C Check for Damage OUTPU...

Page 6: ...EDs of the front panel will light up for 2 seconds The green light up continuously This indicates normal operation Note If the UPS continues to beeps or the green light is not alight even mains power...

Page 7: ...c 1 beep every 4 sec Power failure UPS is battery mode 1 beep every sec Battery low UPS is in battery mode batteries are nearly axhausted and UPS will be shut down 1 beep every 2 sec Battery weak UPS...

Page 8: ...n Power cord defective Please contact your dealer Plug the UPS into a working wall outlet for at least Grenn LED blinks very low battery voltage 8 hours to recharge the batteries If the problem red LE...

Page 9: ...itter 8 AC Fail open emitter 9 AC Fail open collector The DB 9 communication port allows the status of UPS to be monitored data to be backed up computer to be switched off COMMUNICATIONS The PowerSure...

Page 10: ...20 load 20s to shutdown Battery mode 120 load 5s to shutdown BATTERY PARAMETERS Model Number PSPXT450 230 PSPXT700 230 PSPXT1250 230 Type Valve regulated nonspillable lead acid Quantity x Voltage x 1...

Page 11: ...ident abuse neglect negligence unauthorized modification alteration or repair use beyond rated capacity or improper installation maintenance application or use including without limitation use in a ma...

Page 12: ...han 1000 kVA Integrated systems that provide both environmental and power protection in a single flexible package Monitoring and control on site or remote from systems of any size or location Service...

Reviews: