background image

13

Technical Support

U.S.A.

1-800-222-5877

Outside the U.S.A.

614-841-6755

U.K.

+44 (0) 1793 553355

France

+33 (0) 1 43 60 01 77

Germany

+49 89 99 19 220

Italy

+39 2 98250 1

Netherlands

+31 (0) 475 503333

E-mail

upstech@liebert.com

Web site

http://www.liebert.com

Worldwide FAX tech support

+614-841-5471

The Company Behind The Products

With more than 500,000 installations around
the globe, Liebert is the world leader in
computer protection systems.  Since its
founding in 1965, Liebert has developed a
complete range of support and protection
systems for sensitive electronics:

 Environmental 

systems: 

close-control 

air

conditioning from 1.5 to 60 tons.

 

Power conditioning and UPS with power
ranges from 250 VA to more than 1000 kVA.

  Integrated systems that provide both

environmental and power protection in a
single, flexible package.

 

Monitoring and control — on-site or remote —
from systems of any size or location

 

Service and support, through more than 100
service centers around the world, and a 24-
hour Customer Response Center.

300- 500 VA

230V

P

OWER

S

URE™ 

P

ERSONAL

While every precaution has been taken
to ensure accuracy and completeness of
this literature, Liebert Corporation
assumes no responsibility, and
disclaims all liability for damages
resulting from use of this information or
for any errors or omissions.

©1999 Liebert Corporation All rights
reserved throughout the world.
Specifications subject to change without
notice.

® Liebert and the Liebert logo are
registered trademarks of Liebert
Corporation.  All names referred to are
trademarks or registered trademarks of
their respective owners.

SLI-23265 (5/99) Rev. 1

Summary of Contents for PowerSure Personal

Page 1: ...USER MANUAL 300 500 VA 230V POWERSURE PERSONAL...

Page 2: ...FOR OTHER APPLICATIONS Store in safe place if not required at this time 4 This UPS must be earthed at all times during operation Connect only to a mains supply socket outlet with an earth connection...

Page 3: ...cart stand or table Do not place UPS under direct sunlight or close to heat emitting sources Do not place UPS power cord in any area where it may get damaged by heavy objects Follow all warnings and i...

Page 4: ...ptible Power System UPS It provides conditioned power to microcomputers and other sensitive electronic equipment MAJOR COMPONENTS Mains Battery LED Warning LED Liebert R P er sonal Pow erSure TM Power...

Page 5: ...Per sonal Pow erSure TM Check for Damage Liebert R Per sonal Pow erSure TM Liebert R Per sonal Pow erSure TM 110 mm 0 40 C Press ON Button for 2 seconds Remove Plug from Unit and replace in UPS Plug U...

Page 6: ...ated green 6 Check the operation of your load equipment it should display normal operational conditions 7 If any function provides an abnormal condition refer to the trouble shooting guide later in th...

Page 7: ...inuous Beep UPS Failure Battery Mode Mode Green Red Alarm Indicates Back Up Flash Every 3 sec OFF Beep Every 3 sec UPS is on Battery UPS Fault Flash Every 3 sec ON Continuous Beep No Output Low Batter...

Page 8: ...voltage below threshold AC overvoltage Plug in power cord securely Replace fuse and restart UPS Call a qualified electrician Wait until voltage rises to appropriate level Voltage must be higher than...

Page 9: ...eral signals are provided on this port and are assigned as follows PIN ASSIGNMENT DESCRIPTION 1 Low Battery open collector 2 No connection 3 No connection 4 On Battery Mode Shutdown 5 12V DC 5 On Batt...

Page 10: ...t and pull fuse holder out to remove AC Inlet Fuse Holder Input Fuse Spare Fuse CAUTION Before changing the supply fuse turn off the UPS and unplug the input mains lead from the AC mains socket and fr...

Page 11: ...Utility and Battery Modes Overload Warning 15 25 W Overload Warning 20 45 W BATTERY PARAMETERS Type Valve regulated nonspillable lead acid Quantity x Voltage x Rating 1 x 12V x 4 5 Ah 1 x 12V x 7 0 Ah...

Page 12: ...ident abuse neglect negligence unauthorized modification alteration or repair use beyond rated capacity or improper installation maintenance application or use including without limitation use in a ma...

Page 13: ...e than 1000 kVA Integrated systems that provide both environmental and power protection in a single flexible package Monitoring and control on site or remote from systems of any size or location Servi...

Reviews: