background image

 

11

SPECIFICATIONS 

FCC ID # 

N/A 

BHKAF400T-60 

BKAF600T-60 

Model # / Stock # 

PS250-60/PS250-60S 

PS400-60 / PS400-60S 

PS600-60 / PS600-60S 

Model Rating 

250 VA / 150 W 

400 VA / 240 W 

600 VA / 360 W 

Dimensions 
Unit (W x D x H) 

3.51 x 10.18 x 6.79 in 

(90 x 262 x 175 mm) 

4.25 x 10.18 x 7.02 in 

(109 x 262 x 186 mm) 

4.84 x 10.18 x 8.15 in 

(124 x 262 x 216 mm) 

Shipping (W x D x H) 

7.13 x 14.37 x 11.93 in 

(181 x 365 x 303 mm) 

8.35 x 18.98 x 11.5 in 

(212 x 482 x 292 mm) 

9.33 x 18.98 x 13.15 in 

(237 x 482 x 334 mm) 

Weight 
Unit 

8.8 lb. (4 kg) 

12.5 lb. (5.7 kg) 

 19.8 lb. (9 kg) 

Shipping 

10.1 lb. (4.6 kg) 

15.4 lb. (7 kg) 

23.1 lb.(10.5 kg) 

AC Parameters 
Receptacles 

(2) NEMA 5-15 

(4) NEMA 5-15 

(4) NEMA 5-15 

Input Voltage Range 

90-135 VAC, Single Phase, 2 Wire Plus Ground 

Low Voltage Transfer Point 

95 VAC, User Selectable to 90 or 100 VAC 

High Voltage Transfer Point 

135 VAC 

135 VAC, User Selectable to 140 VAC 

Input Frequency Range 

47 – 53 Hz,  57 – 63 Hz 

Output Voltage (on battery) 

115 VAC, ± 5% 

Output waveform (on battery) 

Stepped Sine Wave 

Max. Output Current at 120 V 

2.1 A 

3.3A 

5 A 

Output Frequency 

50 or 60 Hz, ±5% 

Max. Overload Capacity 

115% of Power Rating 

Battery 
Type 

Sealed, Valve-Regulated Lead Acid, Maintenance-Free 

Qty x Voltage x Rating 

1 x 12 V x 4.5 AH 

1 x 12 V x 7 AH 

2 x 12 V x 7 AH 

Back-up Time 

6 minutes at full load 

Time from Low Battery Alarm 
to Shutdown 

 

Approximately 2 Minutes, depending on load 

Recharge Time 

8 – 10 Hours to 90% Capacity 

Battery Life 

3 – 5 Years Typical 

Transfer Time to/from Inverter 

2 – 6 msec. Typical 

Agency Approvals 
Safety 

UL, C-UL Listed 

EMI / RFI 

Meets FCC Part 15, Subpart B, Class B 

Surge Protection 

Meets IEEE 587, Category A and B 

MTBF (Bellcore Method) 

100,000 Hours (Excluding Battery) 

Environmental Standards 
Operating Temperatures 

50° F to +104° F (10° C to +40° C) 

Storage Temperatures 

0°  F to +104° F (-20° C to +40° C) 

 (High Temperatures Reduce Battery Life) 

Cooling 

Convection 

Audible Noise 

Less than 40 dB @ 1 meter 

Operating Elevation 

Up to 9,900 ft. (3,000 m) 

Storage Elevation 

Up to 33,000 ft. (10,000 m) 

 

Summary of Contents for PowerSure PS250-60S

Page 1: ...PowerSure POWER PROTECTION Uninterruptible Power System 250 VA 600 VA 115 V USER S MANUAL English R PS250 60S 250 VA PS400 60S 400 VA PS600 60S 600 VA...

Page 2: ...es or corrosive substances 6 WARNING Do not modify cable Consult dealer if connector does not match equipment UPS must be grounded at all times while in use Turn UPS OFF before unplugging or the safet...

Page 3: ...art up The UPS resets the counter after back up operation manual battery test or if the UPS is switched OFF The operator may perform a manual battery test by pressing the BATTERY TEST button on the ba...

Page 4: ...If any appear faulty or damaged contact your dealer immediately Store the packaging in a safe place for possible future shipment of UPS 3 Place the UPS on a sturdy dry surface in a well ventilated ar...

Page 5: ...be unlit 5 Check the operation of your equipment It should display normal operational conditions 6 If any function provides an abnormal condition refer to the troubleshooting guide later in this manu...

Page 6: ...NDOWS and many others SiteNet 1 software automatically performs an orderly shutdown of computer operating systems in the event of a power outage and or low battery conditions The SiteNet 1 kit supplie...

Page 7: ...s at 140VAC Factory setting is 135 VAC Option Switch 3 4 Low Voltage Transfer Select Low voltage transfer is the voltage level at which battery operation starts You may set the low voltage transfer of...

Page 8: ...OFF UPS and unplug it from utility supply CAUTION Observe proper precautions When replacing batteries use the same number and type of batteries Proper battery disposal required Refer to local codes f...

Page 9: ...ity overvoltage Wait until utility voltage rises to appropriate level Check circuit breaker at rear of UPS 9 If it is activated reset it and restart the UPS See Resetting Circuit Breaker If problem pe...

Page 10: ...Audible Alarm Status NORMAL START UP On Flash Once then Off Off Single Beep and then Off Operate Start Up Test Fail Off Off On Continuous for 15 Sec and then Off Will Not Start Input Frequency Mismat...

Page 11: ...Hz 57 63 Hz Output Voltage on battery 115 VAC 5 Output waveform on battery Stepped Sine Wave Max Output Current at 120 V 2 1 A 3 3A 5 A Output Frequency 50 or 60 Hz 5 Max Overload Capacity 115 of Powe...

Page 12: ...unauthorized modification alteration or repair use beyond rated capacity or improper installation maintenance application or use including without limitation use in a manner contrary to the accompanyi...

Page 13: ...ecaution has been taken to ensure accuracy and completeness in this manual Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information...

Reviews: