BATTERY CARE AND USE 

 
STORAGE: If the unit is not in continued use, plug in the UPS every 4 to 6 
months for 12 hours to recharge the battery. Warranty is void if the battery 
discharges below the minimum battery cutoff point.  To prevent such discharge, 
DO NOT leave UPS ON for more than two days without plugging it in.  
 
BATTERY LIFE & REPLACEMENT: Excessive battery use, storage at high 
ambient temperatures, and lengthy periods in a discharged state greatly reduce 
battery life.  Your UPS maximizes battery life by limiting the depth of battery 
discharge. You may replace the UPS battery yourself, but if you feel unqualified, 
refer battery replacement to qualified personnel.  Contact your local dealer or call 
Liebert for a replacement battery. 
  
WARNING: To replace batteries, turn OFF UPS and unplug it from utility supply.  
 
CAUTION: Observe proper precautions.  When replacing batteries, use the 
same number and type of batteries. Proper battery disposal required. Refer to 
local codes for disposal requirements. DO NOT OPEN OR MUTILATE 
BATTERY.  RELEASED ELECTROLYTE IS HARMFUL TO SKIN AND EYES 
AND IS TOXIC.
 
 
To Replace the Battery:  
1. 
Close active programs and turn off 

computers.  Turn OFF the UPS and 
unplug it from utility supply.  

 
2. Place UPS on its side and remove retaining 

screws (A) to battery door (B).  

 
3. Open battery door (B) and remove the 

battery (C) by pulling on the battery tab (D).  

 
4. Remove terminal wires (E) from old battery.  

Connect terminal wires (E) to new battery 
(C); the red connects to the positive 
terminal, the black connects to the 
negative. DO NOT reverse terminal 
connections. Slide battery (C) into unit, and 
close battery door (B). Dispose of used 
battery properly (it contains lead and acid).  

 
5. Plug in UPS, turn it on, and charge 

batteries for 8 to 10 hours.  

 

Summary of Contents for PowerSure PS250-60S

Page 1: ...PowerSure POWER PROTECTION Uninterruptible Power System 250 VA 600 VA 115 V USER S MANUAL English R PS250 60S 250 VA PS400 60S 400 VA PS600 60S 600 VA...

Page 2: ...es or corrosive substances 6 WARNING Do not modify cable Consult dealer if connector does not match equipment UPS must be grounded at all times while in use Turn UPS OFF before unplugging or the safet...

Page 3: ...art up The UPS resets the counter after back up operation manual battery test or if the UPS is switched OFF The operator may perform a manual battery test by pressing the BATTERY TEST button on the ba...

Page 4: ...If any appear faulty or damaged contact your dealer immediately Store the packaging in a safe place for possible future shipment of UPS 3 Place the UPS on a sturdy dry surface in a well ventilated ar...

Page 5: ...be unlit 5 Check the operation of your equipment It should display normal operational conditions 6 If any function provides an abnormal condition refer to the troubleshooting guide later in this manu...

Page 6: ...NDOWS and many others SiteNet 1 software automatically performs an orderly shutdown of computer operating systems in the event of a power outage and or low battery conditions The SiteNet 1 kit supplie...

Page 7: ...s at 140VAC Factory setting is 135 VAC Option Switch 3 4 Low Voltage Transfer Select Low voltage transfer is the voltage level at which battery operation starts You may set the low voltage transfer of...

Page 8: ...OFF UPS and unplug it from utility supply CAUTION Observe proper precautions When replacing batteries use the same number and type of batteries Proper battery disposal required Refer to local codes f...

Page 9: ...ity overvoltage Wait until utility voltage rises to appropriate level Check circuit breaker at rear of UPS 9 If it is activated reset it and restart the UPS See Resetting Circuit Breaker If problem pe...

Page 10: ...Audible Alarm Status NORMAL START UP On Flash Once then Off Off Single Beep and then Off Operate Start Up Test Fail Off Off On Continuous for 15 Sec and then Off Will Not Start Input Frequency Mismat...

Page 11: ...Hz 57 63 Hz Output Voltage on battery 115 VAC 5 Output waveform on battery Stepped Sine Wave Max Output Current at 120 V 2 1 A 3 3A 5 A Output Frequency 50 or 60 Hz 5 Max Overload Capacity 115 of Powe...

Page 12: ...unauthorized modification alteration or repair use beyond rated capacity or improper installation maintenance application or use including without limitation use in a manner contrary to the accompanyi...

Page 13: ...ecaution has been taken to ensure accuracy and completeness in this manual Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information...

Reviews: