Make sure that the working area is lightened well. 

 

Do not pull the plug out of the wall socket or extension lead by its lead.  

 

Check the feeder cable’s 

outer casing 

and if in use extension lead’s 

outer casing before you connect the 

machine to the electrical mains. The outer casing may not be damaged. Replace the cable if you cannot read 
the marks on the outer casing anymore. 

 

Do not use the machine in an explosion endangered area. 

 

Regularly check the connections of the supply-cable to the switch. 

 

Ensure that the wall socket and possible connections between the extension leads are protected against 
dampness.  

 

The PRCD will automatically switch off  the machine, when the electrical power cuts off.  
This prevents the machine from starting suddenly when the electrical power comes on again.  

 

Check the machine’s cable

-connections before you connect the machine to the electrical mains. The cables 

must be properly connected.  

 

After use, place the poker vibrator on a stable and dry surface. 

 

When the poker vibrator is not being used for longer period, then it must be stored in a dry and clean area.  

 

When cleaning the poker vibrator, ensure that no water or cleaning detergent gets into the poker vibrator. 

 

Disconnect the electrical supply to the poker vibrator, before you start to clean or maintain the poker vibrator. 

 
 

 
2.3  Rest risk 

The manufacturer aimed for the best balance in functionality, safety and operation possibilities of the LHF/HS-ER. 
 
Please take notice of the following rest: 

for prolonged working with LHF/HS-ER poker vibrators it is obligated to 

wear anti vibration gloves. 

 
Well instructed operators with a correct working attitude concerning safe operating are well capable of working 
safely with the LHF/HS-ER poker vibrator. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for LHF/HS-ER

Page 1: ...KER VIBRATOR WITH INTEGRATED INVERTER LHF HS ER LIEVERS HOLLAND Groot Mijdrechtstraat 68 3641 RW Postbus 103 3640 AC Mijdrecht NL Tel 0031 0 297 231900 Fax 0031 0 297 231909 E mail info lieversholland...

Page 2: ...Lievers B V NL 2016 All rights are reserved Reprints copies adaptations for new editions and publications in any form or through any media including abstract forms are not permitted unless written pe...

Page 3: ...ed by Ignoring safety and using instructions as described on the machine or the instruction manual Incompetent or incorrect maintenance e g irregular cleaning of the ventilation slots and cleaning wit...

Page 4: ...lar maintenance of the machine improves safe operation On working areas take notice and follow general and local safety regulations Before starting your work make sure that you are informed about all...

Page 5: ...uddenly when the electrical power comes on again Check the machine s cable connections before you connect the machine to the electrical mains The cables must be properly connected After use place the...

Page 6: ...m 35cm 70 db A 2 5 m s 8hr 32hr 230V 50Hz 2 2 A 12 000 310mm 45cm 72db A 2 5 m s 8hr 32h 230V 50Hz 2 8 A 12 000 320mm 55cm 75db A 2 5 m s 8hr 32h 230V 50Hz 3 6 A 12 000 370mm 65cm 77db A 2 5 m s 8hr 3...

Page 7: ...7 16 Operation manual LHF HS ER edition 1 3 06 02 2019...

Page 8: ...er vibrator 1 Ensure that the poker vibrator s diameter corresponds with the consistency of the concrete 2 Ensure that the supplied voltage of the mains or power supply corresponds with the poker vibr...

Page 9: ...chapter 5 maintenance After use place the complete poker vibrator on a dry and stable surface Application examples The distance between two vibration places and the vibration time in one place depend...

Page 10: ...vervoltage Output voltage 230 Volt 10 200 Hz 3 ph Capacity 1 5 kVA max Output current 5 5 Amp Cable length 20 meter Housing Aluminium Protection IP 65 The electronic components are covered with a spec...

Page 11: ...should be put on an appropriate stand and left to hang TIP IN CASE OF FAILURE OR BREAK DOWN OF THE POKER VIBRATOR WE ADVISE YOU TO SEND THE MACHINE TO AN AUTHORISED LIEVERS SERVICE STATION WARNING WE...

Page 12: ...ant to keep certain spares on stock then please contact the manufacturer dealer for advice When ordering parts please state the following information Type of poker vibrator Year of construction Order...

Page 13: ...16 Operation manual LHF HS ER edition 1 3 06 02 2019 8 Part lists 20 21 22 23 24 20 6 25 26 27 29 30 32 31 33 34 51 52 61 3 60 52 54 55 2 53 53 37 22 36 38 36 Figure 5 Exploded view LHF HS ER HD bott...

Page 14: ...0010 137080011 137080012 137080013 0231 137080014 1400013 137080015 137080016 137080017 137080018 0019 0437 0012 13090 0030 137080020ER 137080021 1300650011 1300570012 n a 1300650020N 1300650030 13006...

Page 15: ...1 Excentric 7 1300360090REK 1300500090REK 1300570090REK 1 Rotor 8 1300360100 1300500100 1300500100 1 Bearing bushing 9 1300360114K 1300500114KN 1300570114KN 1 Stator 230V 10 1300360120 1300500120 1300...

Page 16: ...es that The high frequency poker vibrator LHF HS ER 1 complies with the regulations in the Machine Directive directive 2006 42 EC the EMC Directive directive 2004 108 EC Directive 2002 44 EC and Direc...

Reviews: