43
Interface
Board
Polar
Cable
Single Board
Computer
Mounting
bracket
Lifecycle Recumbent Bikes LC95R, LC91R, LC85R, R9, R7, 95Ri, 93Ri, 90R, and 95Re
How To... Replace the Interface Board
Special Service Tools Required: NONE
CAUTION! BEFORE REPLACING
CIRCUIT BOARD(S), GROUND
YOURSELF TO EARTH GROUND
USING AN ANTI-STATIC GROUND
STRAP.
1. Remove the console from unit refer to
Display Console and Accessory Tray
Removal.
2. Remove seven screws from the Back
Cover.
3. Remove Single Board Computer
4. Disconnect all Cables from the
interface board.
5. Remove 5 screws securing the
Interface Board to the mounting
bracket.
CAUTION! HIGH VOLTAGE ON INTERFACE
BOARD CONNECTORS J2 AND J3.
6. Remove the Interface Board.
7. Install board in reverse order. Been careful on connecting the single board computer to the machine
interface board.
Summary of Contents for 90R
Page 2: ......
Page 6: ...iv Lifecycle Recumbent Bikes LC95R LC91R LC85R R9 R7 95Ri 93Ri 90R and 95Re GLOSSARY PENDING ...
Page 10: ...viii Lifecycle Recumbent Bikes LC95R LC91R LC85R R9 R7 95Ri 93Ri 90R and 95Re NOTES ...
Page 24: ...2 Lifecycle Recumbent Bikes LC95R LC91R LC85R R9 R7 95Ri 93Ri 90R and 95Re Notes ...
Page 52: ...30 Lifecycle Recumbent Bikes LC95R LC91R LC85R R9 R7 95Ri 93Ri 90R and 95Re Notes ...
Page 78: ...2 Lifecycle Recumbent Bikes LC95R LC91R LC85R R9 R7 95Ri 93Ri 90R and 95Re NOTES ...
Page 122: ...2 Lifecycle Recumbent Bikes LC95R LC91R LC85R R9 R7 95Ri 93Ri 90R and 95Re Notes ...
Page 148: ...28 Lifecycle Recumbent Bikes LC95R LC91R LC85R R9 R7 95Ri 93Ri 90R and 95Re Notes ...
Page 150: ...2 Lifecycle Recumbent Bikes LC95R LC91R LC85R R9 R7 95Ri 93Ri 90R and 95Re Notes ...
Page 154: ...6 Lifecycle Recumbent Bikes LC95R LC91R LC85R R9 R7 95Ri 93Ri 90R and 95Re Notes ...
Page 155: ......