9
Lifecycle 3500, 4500, 5500 Series Exercise Bikes
TROUBLESHOOTING GUIDE
Symptom:
LEVEL CHANGES DURING PROGRAM
Symptom
Probable Cause
Corrective Action
Level Changes During
Program
Not pedaling fast enough
Loose wire connections
Damaged wire harness
Cuts or depressions in Display
Console overlay
Defective Display Console
Defective Alternator Control
Board
Alternator output low
Defective Alternator
q
Pedal at 80 RPMs
q
Reseat connector at display console,
Alternator Control Board, Alternator and
Battery
q
Check wire harness for damage
q
Replace overlay/bezel
q
Switch Display Consoles
q
Switch Alternator Control Board
q
Check Alternator output. Should be
9-10V. Red probe on output, Black probe
on ground. Pedal and press Start.
q
Switch Alternator
For Assistance
Call:
Life Fitness Customer Support Services
1-847-451-0036 or 1-800-351-3737
Summary of Contents for Lifecycle 3500 Series
Page 1: ...Lifecycle 3500 4500 5500 Series Exercise Bikes Customer Support Services SERVICE MANUAL ...
Page 19: ...15 Lifecyle 3500 4500 5500 Series Exercise Bikes NOTES ...
Page 20: ...16 Lifecyle 3500 4500 5500 Series Exercise Bikes NOTES ...
Page 24: ...4 Lifecycle 3500 4500 5500 Series Exercise Bikes NOTES ...
Page 40: ...16 Lifecycle 3500 4500 5500 Series Exercise Bikes NOTES ...
Page 41: ...17 Lifecycle 3500 4500 5500 Series Exercise Bikes NOTES ...
Page 43: ...2 Lifecycle 3500 4500 5500 Series Exercise Bikes PARTS IDENTIFICATION ...
Page 44: ...3 Lifecycle 3500 4500 5500 Series Exercise Bikes NOTES ...
Page 47: ...3 Lifecycle 3500 4500 5500 Series Exercise Bikes PREVENTIVE MAINTENANCE Continued ...
Page 48: ...4 Lifecycle 3500 4500 5500 Series Exercise Bikes WIRING BLOCK DIAGRAM ...
Page 51: ...7 Lifecycle 3500 4500 5500 Series Exercise Bikes NOTES ...
Page 52: ...8 Lifecycle 3500 4500 5500 Series Exercise Bikes NOTES ...