8
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes
TROUBLESHOOTING GUIDE
Malfunction
Probable Cause
Corrective Action
Battery over-heating.
Reverse polarity.
RED wire to positive (+) lead and BLACK wire
to negative (-) lead.
Battery cable insulation worn
and contacting frame.
Inspect Wires and replace as necessary.
Malfunctioning Display
Console.
Test with known good Display Console.
Replace malfunctioning Display Console.
Malfunctioning Alternator
Control Board.
Test with known good Alternator Control
Board. Replace defective board.
Defective or damaged main
wire harness.
Inspect Main wire harness, and replace if
necessary.
Exercise bike not stable.
Stabilizer foot pads.
Adjust Foot Pads.
Floor surface not level.
Position bike on level surface.
Stabilizer bar not attached
firmly to frame.
Tightened hardware.
Wheel(s) damaged.
Replace damaged wheel(s).
Frame damaged.
Contact Life Fitness Customer Support
Services.
Summary of Contents for Lifecycle upright 9500HR
Page 17: ...11 Lifecycle 9500HR 9100 Series Recumbent Exercise Bikes NOTES Section I ...
Page 18: ...1 Lifecycle 9500 9100 Series Recumbent Exercise Bikes SECTION II DIAGNOSTICS Section II ...
Page 43: ...26 Lifecycle 9500 9100 Series Recumbent Exercise Bikes NOTES ...
Page 75: ...32 Lifecycle 9500HR 9100 Series Recumbent Exercise Bikes NOTES ...
Page 87: ...12 Lifecycle 9500HR 9100 Series Recumbent Exercise Bikes NOTES ...
Page 101: ...14 Lifecycle 9500HR 9100 Series Recumbent Exercise Bikes NOTES ...
Page 108: ...7 Lifecycle 9500HR 9100 Series Recumbent Exercise Bikes NOTES Section VI ...