Attaching the Head to the Manikin:

As  explained  earlier,  NASCO’s  Airway 
Management  Trainer  has  the  ability  to 
be attached to both 

CPARLENE

®

 and any 

of  the  Resusci®  Anne™*  brand  mani-
kins.  To  attach  the  Airway  Management 
Trainer head to the above manikins, you 
must first remove the lung and stomach 
bags if they are attached to the trainer.

Next, turn the head face down and begin 
inserting it at the shoulders. Tip the head 
upward slightly until the two keyways on 
the back of the neck slide under the ring  
and into the top of the torso (Figure 5). 
Now  match  the  single  keyway  on  the 
neck front up to the slot on the backside 
of  the  torso,  and  push  the  head  down 
until it snaps into place. Rotate the head 
back  around  so  that  it  is  facing  up  and 
in the correct position.

Cleaning and Maintenance:

To  clean  the  Airway  Management 
Trainer  you  will  first  need  to  remove 
the  head  from  the  stand.  Next,  take 
the  trainer  to  an  area  with  a  sink  and 
open  counter  space.  Using  the  3  red 
caps supplied, plug off the esophagus 
and the bronchi (Figure 9).

Next, turn the head slightly to the side to 
align the keyways with the slots, and pull 
the head from the stand (Figure 4).

Figure 9

Figure 8

Figure 7

Figure 3

Figure 4

Figure 5

Using the Combitube®:

Thoroughly read and follow the instruc-
tions that come with the Combitube®. 
The trainer will accept either a full-size 
or  a  small  adult  tube.  As  with  a  live 
patient,  it  may  be  necessary  to  back 
the  tube  out  slightly  if  ventilation  can-
not be established.

NOTE: Depending on tube placement, 
the  large  cuff  may  not  accept  the  rec-
ommended  100  ml  of  air.  If  so,  sim-

ply  inflate  the  cuff  to  its  maximum  vol-

ume  (when  the  plunger  stops).  While 
holding  the  plunger  down,  detach  the 
syringe from the blue pilot balloon, and 

proceed.

Removing the Head from the Stand:

To  remove  the  head  from  the  stand, 
the lungs and stomach bag must first 
be  removed.  Do  this  by  sliding  each 
lung  out  from  the  connector  fitting 
and  removing  the  clamp  that  holds 
the stomach in place (Figure 3).

Then use the provided red cap plugs to 
plug  the  esophagus  and  the  left  bron-
chus (Figure 7). This will ensure the sys-
tem is sealed and operational.

Figure 6

Connecting the Airways:

Once  the  head  is  in  place,  connect  the 

CPARLENE

®

  lung  bag  to  the  right  bron-

chus  by  sliding  the  cap  plug  over  the 
white adapter in the bronchus (Figure 6).

Remove  the  Resusci

®

  Anne™*  head 

and  the  connected  section  of  corru-

gated tubing down to the valve. Install 
the  Airway  Management  Trainer  head 

and hook it up to the lung system with 
the  adapter  piece.  Place  the  red  cap 
end  over  the  white  fitting  of  the  right 
bronchus  and  hook  the  other  end  to 
the  lung  bag  valve  nipple  (where  the 
previous  corrugated  tubing  had  been 

connected).

To remove the head from the manikin, 
reverse the attachment procedure.

PLEASE  NOTE:  NASCO  recommends 

the use of the provided lubricant or a 

similar  vegetable-based  lubricant  for 
the “Airway Larry” Airway Management 

Trainer.  The  use  of  a  silicone-based 

lubricant  may  cause  damage  to  the 
simulator,  thus  voiding  NASCO’s  war-

ranty on the trainer.

To  remount  the  head  on  the  stand,  
simply reverse this procedure.

NOTE:  Our  Airway  Management  Trainer 
will  fit  on  all  models  of

 

CPARLENE

®

 

and 

Resusci

®

  Anne™*  manikins.  To  adapt 

the  Airway  Management  Trainer  head  to 
the Resusci

®

 Anne™*, we have included 

an adapter piece 

(Figure 8).

 

Stabilize  the  head  on  the  counter 
face-up  (towels  work  well  for  this) 
with  the  plugged  tubes  hanging  over 
the  sink.  Carefully  pour  warm  soapy 
water  (a  mild  dish  soap  works  best) 
into  the  mouth  until  the  water  level 
reaches  halfway  up  the  tongue. 
Now  tilt  the  head  back  and  bring 
the  neck  up  3"  off  the  countertop.

Summary of Contents for LF03699U

Page 1: ...pt overprinting stroke at this size Fill not set to overprint Trapping should be changed when the logo is scaled to different sizes Set black fill to overprint if desired Products by NASCO ikin ikin Airway Larry AIRWAY MANAGEMENT TRAINER LF03699U INSTRUCTION MANUAL ...

Page 2: ...luated In addition this model also allows stu dents to apply cricoid pressure dur ing the intubation procedure Sellick s Maneuver By locating the larynx and depressing the cricoid ring the student may realistically lower the vocal cords farther into the field of view This also effectively closes off the esophagus of the simulator The Airway Management Trainer head can be detached from the training...

Page 3: ...he Combitube Thoroughly read and follow the instruc tions that come with the Combitube The trainer will accept either a full size or a small adult tube As with a live patient it may be necessary to back the tube out slightly if ventilation can not be established NOTE Depending on tube placement the large cuff may not accept the rec ommended 100 ml of air If so sim ply inflate the cuff to its maxim...

Page 4: ...i Anne head and the connected section of corru gated tubing down to the valve Install the Airway Management Trainer head and hook it up to the lung system with the adapter piece Place the red cap end over the white fitting of the right bronchus and hook the other end to the lung bag valve nipple where the previous corrugated tubing had been connected To remove the head from the manikin reverse the...

Page 5: ...Replacement Stomach Kit LF03644U NASCO Pump Spray Lubricant W09919U REN Cleaner Cleaning the Face Normal soil can be removed from the face of the trainer with mild soapy water REN Cleaner W09919U will remove stubborn stains Simply apply REN to the soiled area and wipe clean with a soft cloth or paper towel NOTE Do not use REN Cleaner around the mouth and nostrils as the residue of the cleaner coul...

Page 6: ...r LF01162U Venatech IV Trainer LF03000U CPARLENE Series LF03601U Adult Airway Management Trainer LF03602U Adult Airway Management on Manikin LF03603U Adult Airway Management Head Only LF03609U Child Airway Management Trainer LF03610U Child Airway Management Trainer Head Only LF03611U Child Defibrillation Chest Skin LF03612U Child IV Arm LF03613U Child Blood Pressure Arm LF03614U Child Intraosseous...

Reviews: