Quick Connect Fittings and Tubing
Push the tubing into the quick connect. The collar (gripper )
has teeth which hold the tubing firmly in position while the “O” Ring
provides a permanent leak proof seal.
Check the Seal: Pull on the tubing to see if the seal is secure.
Check for leaks.
Ensure system is depressurized before removing fittings. Push in the
collar against the face of the fitting. With the collar held in this position,
the tube can be removed. The fitting can then be re-used.
collar
To ensure an optimal seal, tubing should be cut with the end square.
An angled cut or distortion of the tubing will not provide an efficient seal
and may cause leaks. Determine the length of tubing needed for
the connection and cut the segment of tubing to the appropriate length.
To Connect:
To Disconnect:
push in collar
push in coller
pull tubing out
quick connect