GENERAL INFORMATION

It is strictly forbidden to copy or reproduce this instruction manual without written permission to do so by 

LIFE home integration

 and will be subject to 

verification.

 Translation into other languages of all 

or part of the manual is strictly forbidden without previous written authorisation from 

LIFE home integration

 and will be subject to 

verification.

 All rights on this document are 

reserved.

 

LIFE home integratio

will not accept responsibility for damage or malfunctions caused by incorrect installation or improper use of products and Users are therefore recommended to read this manual 

carefully.

 

LIFE home integration

will not accept responsibility for damage or malfunctions caused by the use of the operator together with the devices of other manufacturers; such action will render the warranty void 

LIFE home integration

will not accept responsibility for damage or injury caused by non-compliance with the installation, set up, maintenance and use indications contained in this manual and the safety instructions described

in the SAFETY INSTRUCTIONS AND WARNINGS 

chapter.

 With the aim of improving its products, 

LIFE home integration

 reserves the right to bring about alterations to them at any time, without giving

prior 

notice.

 This document conforms to the state of the automation at which it is provided when released for 

sale.

INFORMATION ON THE MANUFACTURER

LIFE home integration 

is the manufacturer of the 

ACER

 operator (and will hereinafter be referred to as manufacturer) and the owner of all rights concerning this 

document.

 The Manufacturer’s information 

required by Machinery Directive 98/37/EC is given below:

• 

Manufacturer:   

LIFE home integration

• 

Address:   

Via I Maggio, 37 – 31043 FONTANELLE (TV) Italia

• 

Telephone:  

+ 39 0422 809 254

• 

Fax:  

 

+ 39 0422 809 250

• 

http:  

 

www.homelife.it

• 

e-mail:    

info@homelife.it

The identity plate bearing the information on the Manufacturer of the operator is 

fixed

 to the control 

unit.

 The plate 

specifies

 the type anddate (month/year) of manufacture of the 

automation.

For further information on technical or commercial issues and technician call-out and spares requests, Clients may contact the Manufacturer or area representative from which the product was 

purchased.

INTENDED USE

• 

ACER operators are designed for opening and closing residential-type sliding gates only. Improper use or use on gates larger than those indicated in the TECHNICAL DATA chapter will

  be considered non-conform to the intended use. The Manufacturer declines all responsibility for improper use. The owner accepts full responsibility for improper use, which will result 

  in the warranty being rendered void.

  Any usage differing from that described above is forbidden.

  The operator may not be installed or used in potentially explosive environments.

  The Fitter must ensure that the environment in which the automation is installed is conform to the operator’s temperature range (see Technical Data chap.).

  The operator is not suitable for use on gates with built-in doors unless the automation is prevented from functioning when the door is open.

•  Motorised

 gates must conform to current European standards and Directives, including EN 12604 and EN 

12605.

•  T

he operator may only be used when in perfect working order and in compliance with the intended use, in the awareness of safety and hazard conditions and in observance with the instructions for installation and 

use.

•  Any

 dysfunctions that may pose threats to safety must be eliminated 

immediately.

•  The

 gate must be stable, properly hung and resistant to 

flexion

 (it must not bend during opening and closure 

movements).

•  The

 operator cannot compensate for faulty or incorrectly hung 

gates.

•  The

 operator may not be used in environments prone to 

flooding

•  Do

 not use the operator in environmental conditions characterised by harsh atmospheric agents 

(e.g.

 Salty 

air).

SAFETY INSTRUCTIONS AND WARNINGS

• 

These general rules must always be respected during the installation, connection, testing, trial run, use and maintenance of the automation.

  The Manufacturer declines responsibility for damage or injury caused by non-conformity with the information supplied concerning installation, trial run, use and maintenance contained

  in this manual, and the failure to observe the safety instructions given below.

  The installation, connection, testing, trial run and maintenance of the operator must be performed by a COMPETENT PERSON aided and supervised by a PROFESSIONAL FITTER.

 

Given the technical, procedural, regulation and legal implications of the work, unauthorised fitters are not permitted.

  Installation requires a practical and theoretical knowledge of mechanics, electronics and electrics, and of sector laws and standards.

  Amateur installation is strictly forbidden as it does not comply with current standards and laws and therefore does not guarantee the safe operation of the automation.

  Do not proceed with installation, connection and trial run in the event of doubts or indecision of any kind.

  This manual must be read carefully and understood before installing the operator. If doubts arise during installation, contact a PROFESSIONAL FITTER or the MANUFACTURER.

  Do not perform adjustments and/or parameter memorisation before installation is complete and only if you have understood the procedures described in this manual.

  Only mount the operator on gates that are perfectly aligned with the sliding tracks and are properly hung. A gate that is not correctly aligned or hung can cause serious injury and/or damage to the operator.

 

The Manufacturer declines all responsibility for damage and faults to the operator caused by non-observance of the instructions contained in this 

manual.

•  Keep

 this manual in a safe and easily accessible place so that it can be consulted rapidly when 

necessary.

•  During

 installation, connection, trial run and usage of the operator, observe all applicable accident prevention and safety 

regulations.

•  In

 the interests of safety and optimal functioning of the operator, only use original spares, accessories, devices and fastening 

apparatus.

•  D

o not perform alterations on any operator device or 

component.

 This type of operation may cause 

malfunctions.

 The Manufacturer declines all responsibility for damage caused by products that have been 

modified.

•  The

 operator should not be used until the setting up procedure described in the STARTING UP chapter has been 

performed.

•  S

hould liquids penetrate inside the operator, disconnect the electricity supply and contact the Manufacturer’s Assistance Service immediately; use of the operator in such conditions may cause hazard 

situations.

•  In

 the case of faults or problems that cannot be resolved using the information contained in this manual, contact the Manufacturer’s assistance 

service.

Storage instructions and warnings

• 

The manufacturer declines all responsibility for damage and faults to operator functioning caused by non-compliance with the storage instructions given below.

•  The

 operator must be stored in closed, dry places, at room temperatures of between –20 and 

+70°C.

•  Keep

 the operator away from sources of heat and naked 

flames,

 which could damage it and cause malfunctions, 

fires

 or hazard 

situations.

•  Keep

 the operator in a horizontal position, but not resting on the 

ground.

Indications and warnings for use

• 

It is the fitter’s duty to perform risk analysis and inform the user/owner of any existing residual risks. Any residual risk detected must be recorded in writing in this manual.

• 

The following residual risks are usually present in moving gates: impact and crushing against the main closure surface; impact and crushing in the opening area; shearing between sliding

 

leaf and fixed part of the track and support during movement; mechanical risks caused by movement.

• 

The Manufacturer will not accept responsibility for damage or injury caused by the non-observance of the information on use contained in this manual, and the failure to observe the safety

  indications given below.

• 

The Manufacturer declines responsibility for damage and malfunctions caused by non-compliance with the instructions for use.

• 

Keep this manual in a safe, easily accessible place, so that it can be consulted rapidly when necessary.

•  Never

 touch the gate or moving parts when they are in 

motion.

•  Remain

 at a safe distance when the gate is in motion: only pass when the gate is completely open and 

immobile.

•  Prevent

 children from playing or standing in the vicinity of the gate or the control organs (radio control), the same precautions should be adopted for disabled persons and 

animals.

•  In

 the event of malfunctions (noisiness, jerky movements, 

etc.)

 suspend the use of the automation immediately: failure to observe this rule may entail serious hazards, risks of accidents and/or serious

  damage to the gate and the 

automation.

 Contact a PROFESSIONAL FITTER and in the meantime use the gate manually by disconnecting the operator (see the OPERATOR RELEASE 

chapter).

•  In

 order to maintain the operator in 

efficient

 conditions, ensure that the operations indicated in the MAINTENANCE chapter are performed at the frequency indicated by a PROFESSIONAL 

FITTER.

•  S

hould liquids penetrate inside the operator, disconnect the power supply immediately and contact the Manufacturer’s Assistance Service; the use of the operator in such conditions may cause hazard 

situations.

•  If

 a problem arises that cannot be resolved using the information contained in this manual, contact the Manufacturer’s assistance 

service.

Summary of Contents for acer

Page 1: ...ES PARA LA INSTALACI N EL USO Y EL MANTENIMIENTO MOTORREDUCTOR ELECTROMEC NICO PARA PORT ES DE CORRER INSTRU ES PARA A INSTALA O USO E MANUTEN O ELEKTROMECHANISCHER SCHIEBETORANTRIEB ANLEITUNGEN UND H...

Page 2: ...nstalace viz obr zek Tab 1 ltal nos automatik hoz tartoz robbantott rajz l sd bra Tab 2 descrizione contenuto scatola attuatore ACER Fig 2 description of the contents of the ACER pack Fig 2 descriptio...

Page 3: ...D 20 15 10 Operating temperature C from 20 a 70 Protection class IP 54 Motor insulation class F D Assembly horizontal with dedicated anchorage plate Dimensions weight 170 plate x 342 x 288 h mm 10 kg...

Page 4: ...age plate R L c Refer to fig 2 2 for the respective heights for 16 or 18 tooth pinions d Lay the electric cable pipes 4 allowing them to protrude and plugging them to prevent them from filling with de...

Page 5: ...blocking the 4 M10 screws 7 and the relative washers with a fixed or tube wrench 10 Assemble the covers on the clamping feet 4 See fig 5 3 Fig 5 AC037 AC4 24P AC6 24 AC8 24 AC4 AC6 AC8 AC012 7 7 AC012...

Page 6: ...taut before the earth wire 2 2 Introducing the electric wires into the operator a To access the ECU remove the cover 2 of the reduction gear removing the two lateral clamping screws 1 b Open the pre p...

Page 7: ...cal knowledge of mechanics electronics and electrics and of sector laws and standards Amateur installation is strictly forbidden as it does not comply with current standards and laws and therefore doe...

Page 8: ...ne maintenance procedures as described in this manual This is the owner s duty Any checking maintenance or repair work must be conducted by a PROFESSIONAL FITTER Always switch of the electricity suppl...

Page 9: ...and garage doors and gates Safety in the usage of motorised doors testing methods EN 12453 2000 Industrial commercial and garage doors and gates Safety in the usage of motorised doors Requisites EN 6...

Page 10: ...Page 15 Address Via Sandro Pertini 3 5 31014 COLLE UMBERTO TV Italia Telephone 39 0438 388592 Telefax 39 0438 388593 http www homelife it e mail info homelife it spot colour CMYK Instruction issue V 1...