background image

10

In

str

uct

io

ns

d'u

tili

sat

io

ne

tv

éri

fic

ati

on

an

nu

elle

In

str

uct

io

ns

d'u

tili

sat

io

n

Pou

rp

rof

ite

rd

'un

lim

ina

tio

nm

axi

mal

ed

es

par

tic

ule

sq

ui

flo

tte

ntd

ans

l'ai

r,o

nv

ous

con

sei

lle

de

lai

sse

rm

arc

her

l'ap

par

eil

con

tin

uel

lem

ent

.

Ser

vez

-vo

us

du

sél

ect

eur

de

vit

ess

e

AR

T/B

ASS

E/H

AU

TE

pou

rc

hoi

sir

la

vit

ess

lev

ée

(15

0p

icu

/m

in)

ou

lav

ites

ser

édu

ite

(75

pic

u/m

in)

.

En

tre

tie

n

On

rec

om

man

ded

efa

ire

une

ins

pec

tio

nan

nue

lle

pou

rp

roc

éde

rau

net

toy

age

et

au

rem

pla

cem

ent

des

col

lec

teu

rs

et/o

ud

uf

iltr

e

HEP

A.J

ete

ze

tre

mpl

ace

zle

sc

olle

cte

urs

qua

nd

c'es

tn

éce

ssa

ire

.

Hab

itu

elle

men

t,l

ec

olle

cteu

rp

rim

aire

est

rem

plac

éc

haq

ue

ann

ée,

tan

dis

qu'o

nre

mpl

ace

lec

olle

cteu

rse

con

dair

tou

sle

str

ois

ans

.

Com

me

cha

que

mai

son

est

dif

fér

ent

ee

nc

eq

ui

con

cer

ne

les

dim

ens

ion

s,l

en

om

bre

de

per

son

nes

,l'

em

pla

cem

ent

,le

sta

ux

d'in

filt

rati

on

etl

esb

eso

ins

du

pro

prié

tair

e,i

le

std

iffi

cile

d'es

tim

er

qua

nd

les

col

lec

teu

rsd

evr

ont

être

cha

ngé

s.

On

glis

se

les

col

lec

teu

rs

pou

rle

ss

orti

r.I

lf

aut

s'at

ten

dre

àu

ne

cer

tai

ne

déc

olo

rat

ion

du

méd

ium

filt

ran

te

t,q

uan

do

nr

em

arq

ue

qu'i

lto

mbe

de

la

pou

ssiè

re

d'un

col

lec

teu

r,c

ela

veu

td

ire

qu'i

le

st

tem

ps

de

le

rem

pla

cer

.A

rrê

tez

l'ép

ura

teu

PFT

,le

ven

tila

teu

r

rot

atif

de

la

fou

rna

ise

etl

ev

ent

ila

teu

réc

upé

rat

ion

de

cha

leu

r

(VR

C).

Ouv

rez

la

por

te

ets

orte

zle

sc

olle

cteu

rs

pou

rv

oir

s'il

ya

une

acc

um

ula

tio

nd

es

ale

té.

Pro

céd

ez

en

mêm

et

em

ps

àu

ne

ins

pec

tio

na

nnu

elle

de

tou

tl

'ap

par

eil.

Ava

nt

de

rem

ettr

ed

es

col

lec

teu

rs

en

pla

ce,

ser

vez

-vo

us

d'un

asp

ira

teu

lec

triq

ue

pou

r

enl

eve

rla

pou

ssiè

re

àl'

int

érie

urd

uc

aiss

on

eta

ux

ale

nto

urs

.A

u

mom

ent

d'in

tro

dui

re

les

col

lec

teu

rs,

ten

ez

com

pte

de

la

pos

itio

n

des

flèc

hes

dire

ctio

nne

lles

eti

nsta

llez

-les

cor

rec

tem

ent

.F

erm

ez

la

por

te

etr

em

ette

zl'

épu

rat

eur

àP

FT,

la

fou

rna

ise

etl

eV

RC

en

mar

che

.

Si

vot

re

épu

rat

eur

àP

FT

ins

tal

ave

cu

ns

yst

èm

ed

e

cha

uff

age

àa

ir

pul

sé,

vou

sd

eve

zc

ont

inu

er

d'u

tili

ser

le

filt

re

rec

om

man

pou

rla

fou

rna

ise

.V

ous

dev

rie

zp

rof

ite

rd

ec

ette

vér

ific

atio

nan

nue

lle

pou

rin

spe

cter

lef

iltr

ed

ela

fou

rna

ise

.

Qua

nd

vou

sa

vez

bes

oin

de

nou

vea

ux

col

lec

teu

rs,

app

ele

zv

otre

con

ces

sio

nna

ire

.

Mod

èle

TFP

300

0HE

PA

-U

nco

llec

teu

rP

FT,

un

filt

reH

EPA

Av

an

td

ec

om

me

nc

er

n'i

mp

ort

eq

ue

lle

ch

e

d'e

ntr

eti

en

,il

fau

td

éb

ran

ch

er

to

ute

sle

ss

ou

rce

sd

e

co

ura

nt.

Summary of Contents for Lifebreath TFP3000HEPA

Page 1: ...ype 2 Installation 7 Type 3 Installation 8 9 Operating Instructions and Annual Check up 10 Wiring Diagram 11 Table of Contents 69 TFP 3000 0911 NOTE Due to ongoing research and product development specifications ratings and dimensions are subject to change without notice Operation and Installation Manual Whole House Air Cleaner Model TFP3000HEPA ...

Page 2: ... TFP Collector TFP Collector Wash prefilter foam every 6 months Primary TFP Collector Replace collector annually Secondary TFP Collector Replace collector every 2 years Due to the performance characteristics of the TFP collector the secondary collector needs to be replaced only every 2 years Rubber mounting pads for TFPC to stand on Exhaust Air Supply Air Model TFPC3000HEPA HEPA Filter TFP Collect...

Page 3: ...arge Is the TFP a patented unique technology or just another filter Airia Energy Systems hold the patent for this TFP technology The TFP series are the only one of its kind How much maintenance is involved How often do the filters need to be replaced As tested under average household dust loading the TFP should be inspected annually Typically the primary collector should be replaced annually and t...

Page 4: ...rizontally Model TFP3000HEPA Motors and Blowers 2 speed high efficiency PSC Motor 150 cfm 75 cfm 110 watts 120 VAC standard three prong plug to receptacle The TFP is equipped with a standard power supply on 5 5 1 6 meters cable OFF LOW HIGH Speed Selector Switch Select 75 cfm Low or 150 cfm High Airflow 150cfm 4 WC High Speed 75 cfm 4 WC Low Speed Model TFP3000HEPA One replaceable TFP collector an...

Page 5: ... 8 32 X 3 4 mounting screws provided through the brackets and into position Tighten and secure 7 TFP should now sit securely against the plenum with the foam in between 8 Cut 2 7 holes in the return air plenum Install ducting to join TFP to the return air plenum Fig 2 OTE Do not support the weight of the TFP on the duct Duct must be open and not pinched OTE Due to possible noise transfer through t...

Page 6: ...ith the TFP is acceptable Consult a certified electrician ATTENTION TYPE 1 INSTALLATION Option C Vertical Design Use Option B when Option A is not practical For cedAir Fur nace Return Air Supply Air Air Cleaner The furnace fan and or HRV must operate continuously for Type 1 and Type 2 installations If they do not operate continuously then interlocking them electrically with the TFP is acceptable C...

Page 7: ... prevent pressure differences 4 A short piece 1 2 foot of flexible ducting should be used on both sides of the TFP Fig 3 to reduce vibration and noise transfer OTE Please refer to the HRV installation manual for proper ducting of that appliance Breathing T The Breathing T is designed to assist in neutralizing pressure differences which can occur between the HRV and the TFP when joined together The...

Page 8: ...ller than the size of the port collars 7 on the TFP 4 Ductwork should be kept as short and straight as possible to allow for good air circulation ote For installations of more than one return or supply greater than 5 e s p it is often necessary to add an in line fan to the system as a booster TYPE 3 INSTALLATION Independent Duct System No HRV This installation configuration is recommended for home...

Page 9: ...9 TFP3000HEPA Office or Classroom conditioned space TFP3000HEPA TYPE 3 INSTALLATION Alternative Applications Office or Classroom Application Work Table Application ...

Page 10: ...ide out Some discoloration of the collector medium can be expected If loose dust falls from the collector it is time to replace it Turn off the TFP furnace fan and HRV Open the door and slide out the collectors to check buildup and do an annual inspection of the overall unit Before replacing any collectors vacuum any dust inside the cabinet or from the surrounding area When replacing the collector...

Page 11: ...LACK Ground GREEN HIGH SPEED OFF LOW SPEED DEFOND SWITCH 120 VAC 60 Hz FAN MOTOR 1 2 3 TRANSFORMER TERMINAL BLOCK BLACK WHITE BLUE WHITE BLUE BLACK BLACK BLUE RED WHITE RED G GREEN YELLOW 370V 50 60HZ CAPACITOR 10UF DOOR SWITCH RED RED BROWN CAUTION ATTENTION 11 ...

Page 12: ..._Telephone Contact _____________________ Serial Number______________________________________________Installation Date ________________________ Model _________________________________________________________________________________________ Register for your warranty at www lifebreath com Airia will require the Model and Serial Number to register the unit ...

Page 13: ...___Téléphone Contact _____________________ Numéro de série ____________________________________________Date d installation _______________________ Modèle ________________________________________________________________________________________ Pour enregistrer votre garantie visitez le site ww lifebreath com Vous devez avoir les numéros de modèle et de série pour valider la garantie ...

Page 14: ...TESSE ARRÊT BASSE VITESSE COMMUTATEUR DEFOND 120 VCA 60 hertz MOTEUR DU VENTILATEUR 1 2 3 TRANSFORMATEUR BLOC À BORNES NOIR BLANC BLEU BLANC BLEU NOIR NOIR BLEU ROUGE BLANC ROUGE T VERT JAUNE CONDENSATEUR 370 V 50 60 Hz 10 µ F COMMUTATEUR DE PORTE ROUGE ROUGE BRUN CAUTION ATTENTION 11 ...

Page 15: ...filtrant et quand on remarque qu il tombe de la poussière d un collecteur cela veut dire qu il est temps de le remplacer Arrêtez l épurateur à PFT le ventilateur rotatif de la fournaise et le ventilateur à récupération de chaleur VRC Ouvrez la porte et sortez les collecteurs pour voir s il y a une accumulation de saleté Procédez en même temps à une inspection annuelle de tout l appareil Avant de r...

Page 16: ...9 TF P3 00 0H EP A Bureau ou salle de classe Espace climatisé T F P 3 0 0 0 H E P A INSTALLATION DE TYPE 3 Autres utilisations possibles Dans un bureau ou une salle de classe Sous une table de travail ...

Page 17: ... plus petites que le diamètre des colliers d orifice 7 po sur l épurateur à PFT 4 Afin d assurer une bonne circulation de l air les conduits doivent être aussi courts et droits que possible Remarque Pour les installations comprenant plus d un conduit de reprise ou de distribution avec une pression statique extérieure dépassant 0 5 il faut souvent ajouter un ventilateur en ligne pour renforcer le s...

Page 18: ...e l épurateur à PFT Fig 3 vous devrez utiliser une courte pièce 1 à 2 pieds de gaine flexible Vous réduirez ainsi la transmission de la vibration ou du bruit le cas échéant REMARQUE Pour bien canaliser cet appareil n oubliez pas de consulter le manuel d installation du ventilateur à récupération de chaleur VRC T d aération Le T d aération a pour fonction d aider à neutraliser les différences de pr...

Page 19: ...Air repris Air alimenté Épurateur d air Choisissez l option C lorsque l option A n est pas pratique minimum 40 pouces Fournaise à air pulsé Air repris Air alimenté Épurateur d air le ventilateur rotatif de la fournaise doit fonctionner sans interruption pour des installations de type 1 le ventilateur rotatif de la fournaise doit fonctionner sans interruption pour des installations de type 1 ...

Page 20: ...r à PFT doit être placé sur le plénum de manière à laisser des espaces libres suffisants pour les loquets 6 Posez les quatre 4 vis de montage de 8 32 x 3 4 po fournies dans les supports et en position Serrez les pour bien assujettir l assemblage 7 L épurateur à PFT devrait maintenant être bien ajusté contre le plénum avec une couche de mousse entre les deux surfaces 8 Découpez deux trous de 7 pouc...

Page 21: ..._______________ Entrepreneur ____________________________________ Fournisseur _____________________________________ Soumission N o ___________________________________ Présentée par ___________________________________ Moteurs et soufflantes Moteur à condensateur permanent à grande efficacité à deux vitesses 150 pi cu min ou 75 pi cu min Alimentation électrique courant alternatif de 120 volts 110 wa...

Page 22: ... filtre La compagnie Airia détient le brevet d invention pour la technologie du PFT Les appareils à PFT sont les seuls du genre sur le marché L entretien est il compliqué Est ce qu on doit remplacer les filtres souvent À la suite d essais effectués dans des conditions moyennes d empoussiérage on a conclu que l épurateur d air à PFT devrait être inspecté chaque année Normalement le collecteur prima...

Page 23: ...haracteristics of the TFP collector the secondary collector needs to be replaced only every 2 years Rubber mounting pads for TFPC to stand on Exhaust Air Supply Air Model TFPC3000HEPA HEPA Filter TFP Collector T Replace collector annually Replace collector every 3 years Due to the performance characteristics of the TFP collector the Hepa filter only needs to be replaced every 3 years C O N S O L E...

Page 24: ...uctions d utilisation et vérification annuelle 10 Schéma de câblage 11 Table des matières 69 TFP 3000F 0911 N B À cause de notre programme continu de recherches et de perfectionnement des produits les caractéristiques les puissances nominales et les dimensions peuvent être modifiées sans préavis Manuel d installation et d utilisation Entrée de l air Sortie de l air L épurateur d air pour toute la ...

Reviews: